Stationary Electric Air Compressor Manual
11
EXPLODED VIEW & EXPLANATION OF AIR COMPRESSOR FEATURES
STARTER: the Motor starter provides thermal overload protection. The starter is required
from on motors 5 Hp and above.
CAM SWITCH: designates which pump is leading and which is lagging. Will alternate
lead/lag when in the "alternate position".
LOW OIL SHUT DOWN: the low oil sensor will not allow the unit to start when oil level
falls below an adequate level.
VIBRATION ISOLATOR PADS: Isolators protect the unit from vibration during use. They
also make installation on unlevel surfaces easier.
PNEUMATIC DRAIN: Drains liquid from tank automatically as the water level rises in the
tank.
ELECTRIC DRAIN: Drains liquid form the tank using a timer for frequency and duration
of drain.