![Mi-T-M 32-1192 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/mi-t-m/32-1192/32-1192_operators-manual_1783910010.webp)
10
Mi-T-M
®
Corona Discharge Ozone Generator Operator's Manual
OPERATION
START-UP:
Upon completing all of the generator system connections, you are ready to
begin start up procedures.
1. Check electrical connections.
2. Check for proper voltage.
3. Turn on tank circulation system.
4. Check for leaks.
OPERATION:
Turning on the ozone switch will activate the ozone pump and generator. In
some units an additional relay/contactor is used in conjunction with the switch
to control the ozone generator. Open the generator enclosure to confirm
that the light on each ozone module is on when there is power going to the
generator.
The flow rate of the generator has been pre-set to 15 SCFH. The in-line ball
valve in the blue ozone tube should NOT be adjusted or removed. In addition
any gate valves or ball valves in ozone injector line should not be adjusted
either.
When ozone generator is running properly bubbles should be visible from
within the treatment tank. There should also be a noticeable ozone odor
coming from the ozone treated chamber of the tank.
SHUT-DOWN:
The following sequence of steps must be followed for servicing or for storage.
1. Turn off Ozone Power Switch.
2. Turn off water separator power.
3. Turn off main power to water inlet.
4. If the system is to be shut down for an extended period, disconnect the
Ozone Gas Line from the ozone generator.