Manual operation:
The following thermostat functions can also be set without the App.
Function
Key operation
Change the showing ACTUAL
temperature in the display
(internal/external sensor)
Press the "M" key and
▲
for 3 seconds, the display will show
ROOM to the right of the ACTUAL temperature (left display side)
when the value of the internal temperature sensor is displayed. If
ROOM is not displayed, the value of the external temperature
sensor is displayed.
Open the settings menu
Press the
▲
and
▼
button for 3 seconds. Tham press the "M" key
several times to switch between the following settings. The value
of each setting can be changed with the
▲
and
▼
button.
1
Sensor Type
00: internal sensor, 01: external sensor, 02 internal and external
sensor, standard value 00
2
Temperature limitation
external sensor
20 - 95°C / off, standard 35°C, for electric underfloor heating we
recommend 27°C
3
Hysteresis
1
–
9°C, standard 2°C
4
Temperature Calibration
-9
–
+9°C, standard 0°C
5
Temperature limitation
internal sensor
35
–
90°C, standard 35°C
6
Frost protection
0 - 30, standard 5°C
7
Home-Mode Temperature
5
–
35°C, standard 22°C
8
Away-Mode Temperature
5
–
35°C, standard 15°C
9
AUTO-Mode Temperature
standard 20°C, weekly program only adjustable via App
10
Restart device
Press
▲
or
▼
, display changes from "--" to "==", wait 5 seconds.
11
Factory settings
Press
▲
or
▼
, display changes from "--" to "==", wait 5 seconds.
Description of terminals:
1 & 4
Output terminal for connecting the load
2 & 3
Input terminal for the 230V/AC supply voltage of the
thermostat
5 & 6
Input terminal to connect the external temperature
sensor