MHSC Stratford SS38 Скачать руководство пользователя страница 36

46D0232

36

SS38 Direct Vent Gas Stove

REPLACEMENT PARTS 

SS38 Direct Vent Gas Stove

 

SS38DV(B,G)F(N,P) 

SS38DV(B,G)(N,P0

 Ref. 

Description 

qty. 

Natural  

Propane 

Natural 

Propane

  1. 

Burner Assy. 

46D0177 

46D0177 

46D0177 

46D0177

  2. 

Left Log Support Bracket 

46D0251K 

46D0251K 

46D0251K 

46D0251K

  3. 

Right Log Support Bracket 

46D0252K 

46D0252K 

46D0252K 

46D0252K

  4. 

SIT 820 Nova Valve 

37D0117 

37D0118 

37D0117 

37D0118

  5. 

Injector 

57D0209 

57D0680 

57D0209 

57D0680

  6. 

Venturi 

45D0600 

45D0600 

45D0600 

45D0600

  7. 

Tube Valve/Burner 

45D0085K 

45D0085K 

45D0085K 

45D0085K

  8. 

Pilot Assy. 

37D0018 

37D0019 

37D0018 

37D0019

  9. 

Rocker Switch 

41D0048 

41D0048 

41D0048 

41D0048

  10. 

Formed Glass 

46D0159 

46D0159 

46D0159 

46D0159

  11. 

Air Shutter Rod 

46D0211 

46D0211 

46D0211 

46D0211

  12. 

Air Shutter Knob 

45D0237 

45D0237 

45D0237 

45D0237

  13. 

Knob Extension Hi/Lo 

43D0095 

43D0095 

43D0095 

43D0095

  14. 

Knob Extension ON/OFF 

43D0094 

43D0094 

43D0094 

43D0094

  15. 

Ignitor Battery Module 

45D0077 

45D0077 

45D0077 

45D0077

  16. 

Ignitor Wire Harness 

44D0500 

44D0500 

44D0500 

44D0500

  17. 

ON/OFF Wire Harness 

45D0565 

45D0565 

45D0565 

45D0565

  18. 

Louvers 

46D0704 

46D0704 

46D0704 

46D0704

  19. 

Burner Gasket Set 

45D0027 

45D0027 

45D0027 

45D0027

  20. 

Center Log 

46D0222 

46D0222 

46D0222 

46D0222

  21. 

Rear Log 

46D0217 

46D0217 

46D0217 

46D0217

  22. 

Right Base Log 

46D0219 

46D0219 

46D0219 

46D0219

  23. 

Right Top Log 

46D0221 

46D0221 

46D0221 

46D0221

  24. 

Left Top Log 

46D0220 

46D0220 

46D0220 

46D0220

  25. 

Left Base Log 

46D0218 

46D0218 

46D0218 

46D0218

  26. 

Vertical Restrictor (not shown)  1 

45D0551 

45D0551 

45D0551 

45D0551

  27. 

Ceramic Glass Center 

-- 

-- 

46D0160 

46D0160

  28. 

Ceramic Glass Side 

-- 

-- 

46D0158 

46D0158

  29. 

Engine Gasket Set 

45D0033 

45D0033 

45D0033 

45D0033

Fuel Conversion Kits

Natural Gas to LP  

Kit #SS38CKP

LP to Natural Gas 

Kit #SS38CKN

W

ARNING

Failure to position the parts in accordance 
with  these  diagrams  or  failure  to  use 
only  parts  specifically  approved  with  this 
appliance may result in property damage or 
personal injury.

Содержание Stratford SS38

Страница 1: ...electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the...

Страница 2: ...Electrical Wiring 23 Remote Wall Switch 23 Log Placement 24 PLEASE READ THE INSTALLATION OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE Thank you and congratulations on your purchase of a MHSC ga...

Страница 3: ...instructions for future reference IMPORTANT SAFETY INFORMATION This stove is a vented product This stove must be properly installed by a qualified service person The glass door must be properly seated...

Страница 4: ...dth and depth of the appliance 18 Do not use stove if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 19 Do not operate s...

Страница 5: ...see Clearances Page 8 ON O FF PILO T HE AT OF F FA N ST1099 SS38 controls Off Pilot On Knob Optional Remote Receiver Door Figure 1 SS38 Stove Controls Hi Lo Knob On Off RS Switch Blower ST1099 INSTALL...

Страница 6: ...his unit is installed in a mobile home it must be bolted securely to the floor with leg bolts NOTE Stratford SS38 model stove works without any electrical supply Figure 2 Stove Dimensions 2656O 673 mm...

Страница 7: ...e on a metal or wood panel extending the full width and depth of the appliance Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line For opt...

Страница 8: ...er Left and right clearances are determined when facing the front of the heater Follow these instructions carefully to ensure safe installation Failure to follow instructions exactly can create a fire...

Страница 9: ...and 1 minimum to the sides and bottom Vertical sections of this system require a minimum of 1 clearance to combustible materials on all sides of the pipe Only a 1 clearance is required where the vent...

Страница 10: ...required for such venting WARNING Treatment of firestops and construction of the chase may vary from building type to building type These instructions are not substitutes for the requirements of loca...

Страница 11: ...r regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the comb...

Страница 12: ...C Maximum depth of 48 1219mm for alcove location D Minimum width for back wall of alcove location Combustible 38 965mm Noncombustible 24 610mm E Clearance from corner in alcove location Combustible 6...

Страница 13: ...e appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have three locking lugs indentations These lugs will slide straigh...

Страница 14: ...ndoffs between vent cap and exterior wall The vinyl siding standoff prevents excessive heat from melting the vinyl siding material Bolt the vent cap to the standoff Apply non hardening mastic around o...

Страница 15: ...STALLATION Table 1 Horizontal Venting Vertical V Minimum Horizontal H Maximum 5 30 6 8 8 20 NOTE This configuration is for use with corner installation also Figure 15 Horizontal Termination Configurat...

Страница 16: ...n desired location Drop a plumb line down from the ceiling to the position of the burner system exit flue Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a...

Страница 17: ...he base of the flashing to the roof and framing with roofing nails Be sure roofing material overlaps the top edge of the flashing as shown in Figure 18 page 17 There must be a 1 clearance from the ven...

Страница 18: ...o 4 collar of stove or first vent secton as shown VENTING INSTALLATION Figure 21 Cathedral Ceiling Support Box Installation ST1108 cat clg support box Level Cathedral Ceiling Support Box 2 Minimum Bel...

Страница 19: ...rizontal H H1 Minimum Maximum 8 2 9 4 10 6 11 8 23 8 H V1 V V ST1112 vert vent Table 7 Vertical Venting with Two 2 90 Elbows Vertical V V1 Horizontal H H1 Minimum Maximum 8 2 9 12 10 18 11 20 NOTE Ins...

Страница 20: ...as line with gas connector if allowed by local codes not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA...

Страница 21: ...the stove Check your building codes for any special requirements for locating equipment shutoff valve to stoves Apply pipe joint sealant lightly to male threads This will prevent excess sealant from...

Страница 22: ...ob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point Turn unit to high Figure 2...

Страница 23: ...NFPA 70 latest edition and Canadian Electrical Code CSA C22 1 CAUTION Label all wires before disconnecting when servicing controls Wiring errors can cause improper and dangerous operation Verify prop...

Страница 24: ...Install Left Base Log Left Base Log FINAL INSTALLATION WARNING The positioning of the logs is critical to the safe and clean operation of this heater Sooting and other problems may result if the logs...

Страница 25: ...34 Figure 35 Install Top Left Log Top Left Log LG738 VS38 top left log LG738 6 Place top left log on left base log Line up the hole in the bottom of the top log with the locating pins on the bottom l...

Страница 26: ...s and Rock Wool Rock Wool Figure 38 Install Rock Wool Top Center Log Embers Pins FINAL INSTALLATION 8 Place top center log on top left log pins sand angle to burner Figure 37 LG740 9 Break up rock woo...

Страница 27: ...d service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to i...

Страница 28: ...the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in serio...

Страница 29: ...his switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 40 Lighting the burner Depr...

Страница 30: ...for typical burner flame Refer to Figure 45 for typical pilot flame FIREBOX CLEANING 1 Carefully remove log set and embers from combustion chamber 2 Vacuum burner compartment thoroughly 3 Vacuum any...

Страница 31: ...djusted for high altitude as follows To increase air mixture push up the adjustment rod located beneath the stove This opens the shutter more and will stop or minimize sooting Figure 46 To decrease ai...

Страница 32: ...iece glass style frame slide new glass into the 45 aluminum post not shown 7 Fasten retaining brackets back into place with 5 16 nuts 8 Replace 7 8 rope Make sure the joint is at the bottom and there...

Страница 33: ...33 46D0232 SS38 Direct Vent Gas Stove blower Blower wiring diagram for Blower ST1118 blower White Hi Temp ST1119 VS38 wiring diagram...

Страница 34: ...for spark arcing from the electrode to pilot Adjust by loosen ing screws on pilot base Adjust and retighten 4 Replace with new wire 1 A Check for proper connection of thermocouple to rear of valve B...

Страница 35: ...35 46D0232 SS38 Direct Vent Gas Stove replacement parts 1 4 17 9 14 13 6 15 16 19 7 10 5 11 12 2 21 24 22 3 18 AA Battery 25 23 20 8 2030245 VS38 parts...

Страница 36: ...1 43D0094 43D0094 43D0094 43D0094 15 Ignitor Battery Module 1 45D0077 45D0077 45D0077 45D0077 16 Ignitor Wire Harness 1 44D0500 44D0500 44D0500 44D0500 17 ON OFF Wire Harness 1 45D0565 45D0565 45D056...

Страница 37: ...VA 16A Wall Thimble 46DVA WT Cathedral Ceiling Support Box 46DVA CS Roof Flashing 0 12 6 12 46DVA F6DS Roof Flashing 7 12 12 12 46DVA F12DS 4 x 6B x 45 Elbow 46DVA 45B Vinyl Siding Standoff 46DVA VSS...

Страница 38: ...with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please rea...

Страница 39: ...er use or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by mechanical systems such as furnaces fans clothes dryers etc Ter...

Страница 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: