24
87D0174
SSTB11 Woodburning Fireplace
Applying Decorative Trim To The Fireplace
The face of your fireplace may be left exposed or trimmed with any noncombustible material such
as brick, stone or marble. If a trim is installed, be sure it is fastened snugly to the face of the fire-
place. A crack between the material and the face of the fireplace could pose a fire hazard and im-
pair the proper operation of the fireplace. Blocking the fireplace with framing and attaching the base
to the supporting floor will further reduce the possibility of such a crack developing.
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the
mortar joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap the
sides of the fireplace face. Seal the face of the fireplace to the surrounding wall with non-combus-
tible caulk or trim materials to prevent cold air leakage around the fireplace.
TRIM INSTALLATION
&0
TRIMINSTALL
11
56O
”
Min.
12"
Min.
1
56O
”
Min.
Maintain 2” Min. Clearance
to Combustible Construction
from Chimney Pipe
Finish Wall
Header Framing
Noncombustible Required
Below ‘V’ Spacer
Mantel
Top ‘V’ Spacer
Combustible Trim
(See Note)
Glass Doors
NOTE:
Combustible trim must not overlap the black
painted face of the fireplace by more than 1/8”
Noncombustible tile,
brick, stone, etc. materi-
als may be installed over
black painted face of the
fireplace. Special field
fabricated lintel bars may
be installed directly to the
fireplace face as needed
to provide support for the
finishing materials
Glass Doors
FP2190
Figure 30
Cross Sectional View of Fireplace
Upper Panel, Mantel and Framing