MHSC DBX24C Скачать руководство пользователя страница 7

33D4047

7

DFX & DBX Series Vent Free Fireplaces

GETTING STARTED

Make sure you have received all parts:
Check your packing list to verify that all listed parts have 
been received. You should have the following:

 

  Unvented gas heater 

  Trim kit

 

  Two (2) 90°-angle brackets  

  Ceramic fiber logs 

 

  Installation/operating instructions 

 

  Canopy and three (3) screws 

 

  Two (2) anchoring screws 

  Four (4) black screws 

Millivolt  controlled  heater  designed  to  be  operated  with 
optional devices for ON/OFF functions.

 

  Hand held Remote with receiver 

 

  Wall T-stat with 20' wire

 

  Wall switch with 20' wire 

 

• 

Hand held Thermostat Remote w/receiver

PREINSTALLATION INFORMATION

Carefully inspect the contents for shipping damage. If any 
parts  are  missing  or  damaged,  immediately  inform  the 
dealer from whom you purchased the appliance.

 Do not 

attempt to install any part of the appliance unless you 
have all parts in good condition.

What you will need for installation:
You must have the following items available before pro-
ceeding with installation:

 

  External regulator (for propane/LPG only) 

 

  Manual shutoff valve

 

  Piping which complies with local codes 

 

  Sediment trap

 

  Phillips head screwdriver 

 

  Tee joint.

 

  Pipe sealant approved for use with propane/LPG 

 

  Pipe wrench

    (Resistant to sulfur compounds)

W

ARNING

  Handle the gas log burner assembly by 

the grate only. Do not pick the unit up by 
the burners.

  Gloves are recommended when handling 

ceramic fiber logs to prevent skin irritation 
from  loose  fibers.  Logs  are  fragile  —  
handle with care.

In planning the installation for the fireplace it is necessary 
to determine where the unit is to be installed and whether 
optional accessories are desired. Gas supply piping should 
also be planned. The following steps represent the normal 
sequence of installation. Each installation is unique, how-
ever, and might require a different sequence.
1.   Position fireplace in desired location. Refer to the 

Loca-

tion of Fireplace

 and 

Clearances 

and 

Height

 

Require-

ments

,  and 

Firebox  Framing

  sections  found  in  this 

manual. 

 

NOTE:

 Be sure all packing material has been removed 

from underside the unit.

2.   Install  canopy  and  logs  per  instructions  found  in  this 

manual. The canopy MUST be installed for safe opera-
tion of the unit.

3.   Field wire main power supply to units with fan kit. Refer 

to the 

Electrical Section

 found in this manual. (Electrical 

connections  should  only  be  performed  by  an  experi-
enced, licensed certified tradesman).

4.   Install optional ON/OFF kit on units with millivolt control. 

Refer to the installation instructions included with the 
kit and also refer to the 

Electrical Wiring

 section found 

in this manual.

5.   Plumb gas line. Refer to the 

Connecting the Gas

 sec-

tion found in this  
manual. (Gas connections should only be performed 
by an experienced,  
licensed/certified tradesman).

6.   Complete finish wall material and/or surround. 

W

ARNING

Do not install the heater:

  Where curtains, furniture, clothing, or 

other flammable objects are less than 
42" from the front of the heater.

  In high traffic areas.

  In windy or drafty areas.

Содержание DBX24C

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas s...

Страница 2: ...ppearance 21 Operating Instructions 21 For Your Safety Read Before Lighting 22 Manual Control Lighting Instructions 23 Thermostatic Control Lighting Instructions 24 MilliVolt Control Lighting Instruct...

Страница 3: ...Correct installation of the ceramic fiber logs proper location of the heater and annual cleaning are neces sary to avoid potential problems with sooting Sooting resulting from improper installation or...

Страница 4: ...lified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 24 Never burn solid fuels in a fireplace where a unven...

Страница 5: ...livolt 26 000 20 000 DBX24NTC Nat T Stat 10 000 DBX24PTC LP T Stat 10 000 Gas Specifications NOTE For LP models an external regulator is required to reduce supply pressure to a maximum of 13 w c ignit...

Страница 6: ...24Z x 622 mm 32 813 mm B 22Z x 572 mm 28C v 730 mm C 26Z x 673 mm 30 762 mm D 14 356 mm 21C v 553 mm E 17 432 mm 20Z v 514 mm F 4B 118 mm 4C v 121 mm G 4M 124 mm 5 127 mm H 11M 302 mm 13C 340 mm I 1...

Страница 7: ...gs to prevent skin irritation from loose fibers Logs are fragile handle with care In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whet...

Страница 8: ...ted or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floor...

Страница 9: ...ces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS MODEL IN A BEDROOM OR BATHROOM Location should be out of high traffic areas...

Страница 10: ...te height Do not place fireplace on carpeting vinyl tile or other soft floor coverings It may however be placed on flat wood plywood particle board or other hard surfaces Be sure fireplace rests on a...

Страница 11: ...rebox Anchor fireplace to the side framing members using nail ing flanges K J FP2445 opening size Ref DFX24C DBX24C DFX32C J 26C v 26C v 31Z v 680 mm 680 mm 800 mm K 25 25 32ZC zn 635 mm 635 mm 833 mm...

Страница 12: ...ontaining the four log set 3 To remove the grate and base assembly take out two 2 screws as shown in Figure 9 4 Lift grate and base assembly out of the firebox 5 Secure the firebox with two anchoring...

Страница 13: ...0 A sediment trap should be installed upstream to prevent moisture and contaminants from passing through the pipe to appliance controls and burners Failure to do so could prevent the appliance from op...

Страница 14: ...ing to pressure gauge After taking pressure reading reinstall test plug Check for gas leaks FP2499 manual valve NPT Test Plug FP2499 Figure 12 Pressure Test Point Location Manual Control FP2510 thermo...

Страница 15: ...t Spade Terminal FP2112 WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Connecti...

Страница 16: ...omponents may be checked with a millivolt meter having a 0 1000 mV range Conduct each check shown in chart below by connection meter test leads to terminals as indicated A Complete MilliVolt System Ch...

Страница 17: ...and to install canopy FP2513 remove screen Fireplace Screen Louvre FP2513 Figure 17 Remove Fireplace Screen Panel Canopy INSTALL CANOPY 1 Push louvers up and out to remove top louver assem bly 2 Align...

Страница 18: ...rock wool supplied with the unit Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may result in property damage or personal i...

Страница 19: ...left front log Pins LG700 32VFSC logs Pins Left Front Log 2 Left Middle Log 5 Right Front Log 1 Right Middle Log 4 Rear Log 3 Pins Pins LG700 Figure 20 DFX32C Log Placement LG701 24BDXC logs One piec...

Страница 20: ...Figures 23 24 for correct pilot flame If the pilot flame does not touch the thermocouple then the main burner cannot function reliably Refer to Figures 23 24 for incorrect shape of pilot flame Figure...

Страница 21: ...TRUCTIONS Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into the fireplace Do not place a blower inside the burn area of the firebox Ceiling fans may create draf...

Страница 22: ...instruc tions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand d...

Страница 23: ...in push and release the piezo ignitor button to light the ODS pilot The pilot is located on the left side of the heater behind the middle log and in front of the back log If piezo ignitor does not lig...

Страница 24: ...If piezo ignitor does not light the pilot see Match Lighting Instructions Page 26 8 Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas while the...

Страница 25: ...ssary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping 7 With the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Contin...

Страница 26: ...llation of screen DO NOT OPERATE THE UNIT WITH THE SCREEN REMOVED Remove logs handling carefully by holding gently at each end Gloves are recommended to prevent skin irritation from ceramic fibers If...

Страница 27: ...maged 3 Gas regulator defective 1 Vapors from paint or curing process of logs 2 Vapors or smoke continue after heater has run with damper or window open for several hours 1 Turning control knob to HIG...

Страница 28: ...33D4501 33D4501 33D5501 3 Left Firebrick Optional 1 26D7061 26D7061 26D7065 4 Center Firebirck Optional 1 26D7060 26D7060 26D7064 5 Right Firebrick Optional 1 26D7062 26D7062 26D7066 6 Blower Optional...

Страница 29: ...1 11V0313 11V0313 11V0313 11V0313 9 Regulator Valve Tube 5 16 1 33D4512 33D4512 10 ODS Pilot Valve Tube 3 16 1 49D0050 49D0050 49D0050 49D0050 11 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503 12 Pe...

Страница 30: ...11V0313 9 ODS Pilot Valve Tube 3 16 1 49D0050 49D0050 10 Peizo Ignitor 1 14D0503 14D0503 11 Piezo Wire 1 00K0632 00K0632 12 Right Front Log 1 1 33D5042 33D5042 13 Left Front Log 2 1 33D5043 33D5043 14...

Страница 31: ...t Control Valve 1 11V0701 11V0701 6 Pressure Valve Regulator 1 24D0305 24D0306 7 Peizo Wire 1 00K0632 00K0632 8 Burner Valve Tube 1 4 1 33D4053 33D4053 9 Piezo Ignitor 1 18D0402 18D0402 10 Front Log 1...

Страница 32: ...ebox installation The blower must be installed prior to the installation of the unvented heater The electrical connections must be made before the firebox is framed and enclosed in the finished walls...

Страница 33: ...the retainer clip with the hole inside the firebox Using Phillips screwdriver attach the retainer bracket to inside of firebox Figure 37 6 Repeat step five for the other firebrick side panel FP2520 in...

Страница 34: ...ther side trim 6 Slide assembled trim over the top and down the sides of the fireplace Flush trim with front of fireplace as shown in Figure 42 7 Align holes in assembled trim with holes in side of fi...

Страница 35: ...places OPTIONAL ACCESSORIES FP2527 install trim Assembled Trim Trim Flush with Front of Fireplace FP2527 Figure 42 Slide Assembled Trim Over Top of Heater FP2528 secure trim Screws Holes Screw Screw F...

Страница 36: ...so be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident negle...

Отзывы: