Figure 3 - Location of Firebox 

MINIMUM HEARTH DIMENSIONS

GENERAL INSTALLATION INFORMATION

 

  

Figure 2 - Minimum Hearth Dimensions 

Carefully  select  the  best  location  for  installation  of  your 
vent-free  firebox.  The  following  factors  should  be  taken 
into consideration:
  •  Clearance to side wall, ceiling, woodwork and windows. 

See  “Clearances/Height  Requirements  on  page  8. 
Minimum clearances to combustibles 

must be main-

tained.

  •  Location  must  not  be  affected  by  drafts  caused  by 

kitchen exhaust fans, ceiling fans, return air registers 
for forced air furnaces / air conditioners, windows or 
doors.

  •  Installation  must  provide  adequate  ventilation  and 

combustion air.

  • 

DO NOT INSTALL THIS FIREBOX IN A BEDROOM 
OR BATHROOM.

  •  Location should be out of high traffic or windy or drafty 

areas.

  • 

DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS 
ARE LESS THAN 42"  FROM FRONT OF HEATER.

  •  Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation 

air.

  •  Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
  •  Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox 

must be kept clear and free from these combustible materials. 

LOCATION OF FIREBOX

Содержание BUF400

Страница 1: ...00 BUF500 UNVENTED VENT FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS Carefully review the instructions supplied with the decorative type unvented room heater for the mini mum fireplace size requirement Do not install an appliance in this firebox unless this firebox meets the minimum dimensions required for the installation WARNINGS If the information in this manual is not followed exactl...

Страница 2: ...ns 7 Location of Fireplace 7 Clearances and Height Requirements 8 Fireplace Framing 10 Gas Line Installation 12 Canopy and Radiant Face Plates Installation 13 Other Optional Equipment 14 Forced Air Kit 14 Brass or Chrome Louvers 14 Brass or Chrome Trim 14 Firebrick 14 Optional Wide Canopy 14 Illustrated Parts Breakdown 15 Using Optional Outside Air Kit 16 Warranty Back Cover ...

Страница 3: ...gas heater in this firebox IMPORTANT SAFETY INFORMATION 1 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies 2 Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition 3 Young children should be carefully supervised when they are in the same room with the apli ...

Страница 4: ...d are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 per cent for each 1 000 feet above sea level Refer to the National Fuel Gas Code 21 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 22 The appliance mu...

Страница 5: ...e following 1 Vent Free Gas Firebox 3 Five 5 sheet metal screws for canopy 2 Canopy 4 Installation and Operating Instructions What you will need for installation TOOLS BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Piping complying with local codes Wall finishing materials Saw and or sabersaw Tee joint Caulking material noncombustible Level Pipe wrench Fireplace surround ma...

Страница 6: ...erent sequence 1 Position firebox prior to framing or into prepared framing 2 Field wire main power supply to models with fan kit Electrical connections should only be performed by an experienced licensed certified tradesman Electrical outlet is needed with fan kit 3 Plumb gas line Gas connections should only be performed by an experienced licensed certified trades man 4 Install vent free gas log ...

Страница 7: ...s return air registers for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas DO NOT INSTALL WHERE CURTAINS FURNITURE CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42 FROM FRONT OF HEATER Never obstruct the fro...

Страница 8: ...to follow these requirements may create a fire hazard 1 Sidewall clearances The clearance from the inside of the appliance to any combustible wall should not be less than 9 See Figure 4 2 Ceiling clearance The ceiling must be at least 42 from the top of the firebox opening See Figure 4 3 Back wall clearnace The appliance may be placed against a combustible back wall Figure 4 Clearance and Height R...

Страница 9: ...halt tile which is closer than 14 to the base of the firebox See Figure 6 Or The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14 of noncombustible material such as slate or marble is installed between the base of the firebox and the combustible flooring See Figure 7 Figure 5 Mantel Clearances Figure 6 Minimum Clearance above Combustible Flooring Figure 7 Minimum...

Страница 10: ... installation requirements See Figure 1 on Page 6 for firebox dimensions The framing headers may rest on the top of the firebox standoffs The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height When the firebox is installed directly on carpeting tile or other combustible material other than wood flooring the firebox shall be installed on a meta...

Страница 11: ...the firebox Shim if necessary 4 Anchor firebox to the side framing members using 8d nails or other suitable fasteners See Figure 12 5 The canopy must be installed for safe operation of the heater See page 13 for canopy installation details Figure 12 Location of Nailing Flanges Nail Sides Through Nailing Flanges The fireplace must be installed giving full consideration to the clearance and height r...

Страница 12: ... through trap to the heater controls and burners Failure to do so could prevent the heater from operating reliably Consult applicable codes An external regulator must be used on all propane L P G heaters in addition to the regulator fitted to the heater to reduce the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Note W...

Страница 13: ...3 2 Align the canopy with the holes in the top of the frame 3 Secure canopy to front of frame with screws provided See Figure 13 The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater WARNING Close fireplace screen panel before operating a decorative type unvented room heater WARNING Figure 13 Installing Canopy Canopy Screws ...

Страница 14: ... must be installed prior to the installation of the vent free heater The electrical connections must be made before the firebox is framed and enclosed in the finished walls Electrical connections should only be performed by a qualified licensed electrician main power must be off when connecting to main electrical power supply or performing service The blower when installed must be electrically gro...

Страница 15: ...PTION QTY BUF400 BUF500 1 Canopy 1 26D4568 26D4706 2 Screen Panel 2 26D0131 26D0187 3 Screen Rod 2 26D0132 26D0133 4 Rear Refractory 1 61D0102 61D0107 5 Side Refractory 2 61D0101 61D0101 6 Bottom Refractory 1 61D0100 61D0106 7 Outside Air Kit 1 AK 4 AK 4 ...

Страница 16: ...pace or garage space 5 Locate air supply inlet at least 3 away from any appliance vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the free flow of air through the duct See Figures 14 through 17 for methods of installing the outside air for combustion assemblies Figure 14 B...

Страница 17: ...ing collar with duct clamp or screws See Figure 19 DO NOT remove the cover if the outside air will not be connected WARNING Figure 18 Attaching Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Figure 19 Attaching Outside Duct to Starting Collar Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter End of Air Starting Collar Air Starting Coll...

Страница 18: ...Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Installing model 403 duct connector 1 Push insulation back approximately 2 from the end of each duct 2 Slip each duct over duct connector until an equal length of connector extends into each duct 3 Place duck clamp over the end of each du...

Страница 19: ...61D1013 19 ...

Страница 20: ...void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defective parts on the appliance or 3 ...

Отзывы: