Figure 3 - Location of Firebox
MINIMUM HEARTH DIMENSIONS
GENERAL INSTALLATION INFORMATION
Figure 2 - Minimum Hearth Dimensions
Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.
See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles
must be main-
tained.
• Location must not be affected by drafts caused by
kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.
• Installation must provide adequate ventilation and
combustion air.
•
DO NOT INSTALL THIS FIREBOX IN A BEDROOM
OR BATHROOM.
• Location should be out of high traffic or windy or drafty
areas.
•
DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS
ARE LESS THAN 42" FROM FRONT OF HEATER.
• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation
air.
• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox
must be kept clear and free from these combustible materials.
LOCATION OF FIREBOX