ASSEMBLY INSTRUCTIONS THERMOSTATIC SHOWER CB432N
•
Remove various parts from the carton with extreme care.
Disassemble handle in 5 parts: Handle Body (E) – Knob (G) – Cover (H) – CAM (F) – Ring (B)
proceeding as follows:
- unscrew Cover (H) using 3 pin tool here enclosed.
- remove handle center screw.
•
Check on the wall that the built-in thermostatic valve is clean and that installation has been made
correctly according to our separate pre-assembly instructions. In particular, check that the level
pine indicated on the plastic protection lid is posi/-8 mm with respect to the finish wall
level (FIG 1) and that the shower finishing plate covers wall recessed area.
•
At this point remove (by unscrewing) plastic protection lid from the valve body and the two
protection covers from the nozzle on the right.
IMPORTANT: make sure that the valve is closed by fully turning its plastic body clockwise.
ASSEMBLY OF MAIN HANDLE WITH THERMOSTATIC CONTROL
(FIG 2)
•
Place finishing plate (A) on valve body (B
1
) and on nozzles (C
1
e D
1
) pushing it against the wall.
•
Fully screw ring (B) to body (B
1
) keeping knurled area on the outside which will block the ring
to the finishing plate.
•
Fully screw sleeve (C
3
) to nozzle (C
1
), the nozzle’s thread must be outside the covering.
•
Push ring (C
2
) on the sleeve (C
3
) against the finishing plate (the ring’s lower diameter must enter
the plate’s hole).
•
Push hand shower hook (D
2
) on the nozzle (D
1
) against the finishing plate and tighten two grub
screws with allen key attached.
(FIG 3)
•
Push handle (E) on the valve by keeping lever in vertical position (valve is closed).
ATTENTION: Check that the handle is fully pushed in.
(FIG 4)
Insert cam (F) on the large broach of the valve and block to the handle with the 3 allen screws M4
as per (FIG 4A).
(FIG 5)
-Place knob (G) on the valve’s central shaft and rotate until the 3 pins appear through the holes.
-Tighten firmly with screw M4 after positioning washer (R).
-Close by screwing cover (H) on the handle through 3 pin tool to be conserved for future
maintenance.
CHANGING WATER TEMPERATURE AT STOP POSITION
Cam (F) in default position (FIG 4A) determines with an anticlockwise rotation of the knob, a stop
point corresponding to a comfortable warm water temperature. To increase water temperature pull
the knurled ring of the knob and continue anticlockwise rotation. By inverting to clockwise
rotation the stop point will fall back into position.
To change temperature stop point, remove knob (G) (FIG 5), loosen 3 Allen screws (FIG 4a) and
change position of cam (F) (FIG 4). Rotate towards left for warmer water and towards right for
colder water.