Blaze AHRS-2 / AHRS-4 / MAG-2 Operating Manual
Page 19
7 Loading factory default settings
Press and hold the F1/Up button and rotary control during power up to load the pre-
programmed factory default settings. The following screen will be displayed:
Factory default settings can also be loaded in the Miscellaneous setup menu.
8 Error Messages
Unit settings CRC error. Load default settings to restore to factory defaults. If the error
message still persists then it could possibly be a non-volatile memory failure in which
case the instrument will then have to be returned to the factory.
Internal flash CRC error. The instrument does a firmware check on the program when
power is applied to the instrument . If the program is corrupt in any way then the internal
flash CRC error will be displayed. Reload the instruments firmware and load default
settings. If the error message still persists then it could possibly be an internal flash
memory failure in which
case the instrument will then have to be returned to the
factory.
The display will have a red cross over the indicators to signal a SP-X sensor
commu-
nication or sensor failure. Check the communication link between the AHRS-2 /
MAG-2
and the SP-X sensors and that the SP-X sensors themselves are functional.