Page 5

Da = Density altitude
Pa = Pressure altitude
T = ambient temperature in degrees C
Ts= 15 - 0.0019812 * pressure altitude (ft)

Da = Pa + 118.6 * (T-Ts)

3.7 OAT (Outside air temperature) Display

The OAT probe is used to determine density altitude.

4 Menu System

Pressing the rotary control button during the normal display mode will cause the ALT-1 to enter the menu system. Use the 
up/down keys or the rotary control to navigate through the menu system. 

Temperature 
unit

OAT reading

Temporary maximum and 
minimum OAT since 
instrument power up, reset 
using the F1/up key

Local pressure readout (either in 
millibars or in inches of mercury)

Digital VSI readout, 
can be turned off in 
the menu system

Compensated 
density altitude 
value

Altitude unit

Uncompensated 
altitude value

Содержание ALT-1

Страница 1: ...deviation band that has to be kept 1 Features Precision altimeter from 700 ft up to a maximum of 30 000 ft 213m to 9144m Provides altitude encoder data on airtalk serial output which can be converted...

Страница 2: ...2 Button Down button in menu system Main display scrolling in normal mode Rotary Control Up Down Enter Button Press the rotary control during normal mode to access the menu system Rotate anti clockwis...

Страница 3: ...band has been exceeded Digital VSI readout Logarithmic analog VSI indicator VSI units Local pressure readout either in millibars or in inches of mercury Altitude unit Digital VSI readout can be turne...

Страница 4: ...the pilot to enter a reference altitude Enter the reference altitude you would like to use in relative mode Use the rotary control to adjust the reference altitude Press the F1 up key to accept 3 6 D...

Страница 5: ...ontrol button during the normal display mode will cause the ALT 1 to enter the menu system Use the up down keys or the rotary control to navigate through the menu system Temperature unit OAT reading T...

Страница 6: ...o return to the main menu Move the highlight over this menu item and press the rotary button to reset the maximum altitude and airspeed values to the current values 4 3 Display Setup Move the highligh...

Страница 7: ...rcury Hg Select if you want the barometer to be displayed on the altitude screens or not 4 5 VSI Vertical Speed Indicator Setup All VSI related parameters can be setup here Move the highlight over the...

Страница 8: ...few thousand feet above ground and start a glide with a low power setting Take a stopwatch and when the glide is stable stable VSI reading start the stopwatch Take note of your altimeter reading at t...

Страница 9: ...for aircraft transponders Please see the CNV AT operating manual for more information 6 Loading factory default settings Pressing and holding the F1 and F2 simultaneously on power up will cause the A...

Страница 10: ...rotocol 19200 baud 8 data bits no parity 1 stop bit TTL voltage levels 10 Installation Connect the static port to a suitable static air pressure line If you have a slow aircraft or an aircraft were th...

Страница 11: ...sed Warranty is limited to the replacement of faulty components and includes the cost of labour Shipping costs are for the account of the purchaser Damage as a result of applying excessive pressure to...

Страница 12: ...failure or malfunction Under no circumstances does the manufacturer condone usage of this instrument for IFR flights Other instruments in the Stratomaster Infinity series ALT 1 Precision encoding alt...

Отзывы: