11.2 Pressure Port Dimensions
11.3 ASI-4 Cable connections
Main connector (D15 connector: Unit Female, Cable Male)
12 Warranty
This product carries a warranty for a period of one year from date of purchase against faulty workmanship or defective
materials, provided there is no evidence that the unit has been mishandled or misused. Warranty is limited to the
replacement of faulty components and includes the cost of labor. Shipping costs are for the account of the purchaser.
Damage as a result of applying excessive pressure to the pressure ports are excluded from warranty.
D15 Pin
Color
Function
1
Red
8-30Vdc power via power switch / circuit
breaker and fuse.
2
Black
Ground.
3
-
RS232 Transmit data (Firmware upgrading)
4
-
RS232 Receive data (Firmware upgrading)
15
White
Alarm Output (Open collector)
Note:
Product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired
electrical supplies and or sensors, and damage caused by inductive loads.
Inches
Millimeters
Min
Max
Min
Max
A
0.248
0.278
6.30
7.06
B
0.420
0.440
10.67
11.18
C
0.182
0.194
4.62
4.93
D
0.310
0.330
7.87
8.38