background image

 

 

not  less  than  500  ohms  be  connected  between  the  energizer  and  the 
electric fence in this area. 

  The appliance is not intended for use by young children or infirm persons 

without supervision. 

  Do  not  place  combustible  materials  near  the  fence  or  energizer 

connections. In times of extreme fire risk, disconnect energizer. 

  Don't  dismantle.  Don't  make  any  changes  to  this  energizer.  Don't  touch 

high  voltage  parts  which  can  cause  electric  shock.  This  energizer  is  not 
user-servicable. 

  Young children should be supervised to ensure that they do not play with 

the appliance. 

  An  electric  animal  fence  shall  not  be  supplied  from  two  separate 

energizers or from independent fence circuits of the same energizer. That 
is very dangerous. 

  For  any  two  separate  electric  fences,  each  supplied  from  a  separate 

energizer independently timed, the distance between the wires of the two 
electric animal fences shall be at least 2.5m.   

  Barbed wire or razor wire must not be electrified by an energizer. 

  A  non-electrified  fence  incorporating  barbed  wire  or  razor  wire  may  be 

used to support one or more off-set electrified wires of an electric animal 
fence. The supporting devices for the electrified wires shall be constructed 
so as to ensure that these wires are positioned at a minimum distance of 
150  mm  from  the  vertical  plane  of  the  non-electrified  wires.  The  barbed 
wire and razor wire shall be earthed at regular intervals. 

  Where an electric animal fence crosses a public pathway, a non-electrified 

gate shall be incorporated in the electric fence at that point or a crossing by 
means of  stiles. At  any  such  crossing  the adjacent  electrified  wires  must 
carry warning signs.   

  In  areas  of  public  access,  use  an  electric  fence  warning  sign  every  10m 

(33ft) to identify the electrified wire(s). 

  Crossing with overhead power lines should be avoided wherever possible. 

If  such  a  crossing  cannot  be  avoided,  it  should  be made  underneath the 
power line and as nearly as possible at right angles to the power line. 

  If connecting leads and electric fence wires are installed near an over head 

power line, the clearances should be not less than those shown below: 

 

Power Line Voltage 

Clearance 

≤1000 

1000 ≤33000 

33000 



 

  If connecting leads and electric fence wires are installed near an over head 

power line their height above the ground should not exceed 3m. 

Содержание S100

Страница 1: ...1 ELECTRIC FENCING ENERGIZERS USER MANUAL Models MGG S100 and MGG S150 ...

Страница 2: ...2 Contents 1 Introduction 3 2 Important safety introduction 3 3 Specification 6 4 Installation guide 6 5 Maintenance 9 6 Guarantee 10 ...

Страница 3: ...ribes Andmon electronics electric fence energizer of 0 15J model S150 0 1 J model S100 2 Important safety introduction WARNING Please read all instructions Do not touch a live fence Do not drench with water This product is for use in controlling livestock Any other use is prohibited Keep fence clear of weeds branches etc to avoid electrical shorts resulting in battery drainage Do not climb over th...

Страница 4: ...t one or more off set electrified wires of an electric animal fence The supporting devices for the electrified wires shall be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the non electrified wires The barbed wire and razor wire shall be earthed at regular intervals Where an electric animal fence crosses a public pathway a no...

Страница 5: ...e sign shall be black and shall be either the substance of CAUTION Electric Animal Fence or the symbol shown The inscription shall be indelible inscribed on both sides of the warning sign and have a height of at least 25mm Ensure that all mains operated ancillary equipment connected to the electric animal fence circuit provides a degree of isolation between the fence circuit and the supply mains e...

Страница 6: ... Unless otherwise stated values are typical and normal production tolerances of 10 should be allowed for 4 Installation guide Installing the battery 1 Switch 2 Charger input Fence terminal 3 Fence terminal 4 Earth terminal 5 Post mounting slot 6 Solar panel 1 Remove the five M4 screw open panel 2 Remove the four M4 screw open cover 3 You will see the battery Item 8 Use a new battery to change it t...

Страница 7: ... can be mounted directly onto a steel Y post or T post using the post mounting slot To mount onto a wooden post use the hardware provided Thread washers onto the nails Space the nails 75 mm 3 apart or one nail length Hammer in the nails allowing them to protrude by 10 mm 3 8 Slide the energizer onto the nails with the washers inside the post mounting slot Connecting to an electric fence 1 Push a 2...

Страница 8: ...is should have an output voltage of 8 4V and output current not exceeding 1A When fully charged the battery should be able to power the energizer for over two weeks with no sunlight Replacing the battery If a replacement battery is required use a 7 2V 6 8Ah rechargeable lithium battery suitable for all models Do not use a non rechargeable battery Do not dispose of the battery in a land fill or in ...

Страница 9: ...sary clean away any corrosion Check that the earth rod is pushed firmly into firm ground and is not rusty Check for faults in the fence line caused by trees or vegetation If necessary remove obstructions and mend the fence Check that the energizer is adequate for the length of the fence If necessary reduce the length of the fence or reduce the number of fence wires Alternatively divide the fence l...

Страница 10: ...s returned to us together with a copy of the original invoice The unit should be returned in its original or equivalent packaging please preserve the original packing Warranty claims are excluded for direct or indirect damages due to 1 Beyond warranty date 2 Transport damage 3 Improper use operation and refitting 4 Non observance to the relevant safety instructions and work in the severe environme...

Страница 11: ...11 ...

Страница 12: ...12 MGG Products 29C Mill Lane Kerikeri 0230 New Zealand www mggproducts co nz email info mggproducts co nz ...

Страница 13: ...13 The design and specification shall be subject to changes without prior notice The final interpretation right of this event is reserved by our company ...

Отзывы: