7
Operation
Switching on and off
1 When switched on the pulse indicator light flashes once for each output pulse.
2 When switched off the pulse indicator light stops
Energizer maintenance
If using a solar panel, clean the solar panel regularly with a soft cloth using glass cleaner
or a mild solution of detergent and water. This ensures the solar panel functions efficiently.
When transporting the energizer protect the solar panel to prevent the glass surface from
being damaged.
Troubleshooting
Problem and action
1 The Pulse indicator light is flashing, but the electric shock delivered by the fence is
weak.
Check that the energizer is adequate for the length of the fence. If necessary, reduce the
length of the fence or reduce the number of fence wires. Alternatively, divide the fence-line
into smaller zones, with each zone powered by a separate energizer.
NEVER EVER PUT
MORE THAN ONE ENERGISER ON THE SAME WIRE. THAT IS VERY DANGEROUS.
2 The Pulse indicator light is not flashing.
3 The battery needs frequent replacement.
If using a solar panel check that the solar panel is clean and is not damaged. Make sure
the panel is positioned to receive maximum sunlight. If necessary, remove any objects or
vegetation that might be casting a shadow on the energizer. Consider using a larger
capacity battery
5. Maintenance
Warning: Other than changing batteries, there are no user-servicable parts. If repair is
required please contact MGG
.
Fault
Solution
The
Pulse
indicator light is
flashing, but the
electric
shock
delivered by the
fence is weak.
Check that all connections in the fence and earth system are firm
and secure. If necessary, clean away any corrosion.
Check that the earth rod is pushed firmly into firm ground and is
not rusty. Check that there is moisture in the ground.
Check for faults in the fence-line caused by trees or vegetation. If
necessary remove obstructions and mend the fence.
Check that the energizer is adequate for the length of the fence. If