background image

 

 

 

Operation 

Switching on and off 

1 When switched on the pulse indicator light flashes once for each output pulse. 

2 When switched off the pulse indicator light stops   

 

Energizer maintenance 

If using a solar panel, clean the solar panel regularly with a soft cloth using glass cleaner 

or a mild solution of detergent and water. This ensures the solar panel functions efficiently. 

When transporting the energizer protect the solar panel to prevent the glass surface from 

being damaged. 

Troubleshooting 

Problem and action 

1  The  Pulse  indicator  light  is  flashing,  but  the  electric  shock  delivered  by  the  fence  is 

weak. 

Check that the energizer is adequate for the length of the fence. If necessary, reduce the 

length of the fence or reduce the number of fence wires. Alternatively, divide the fence-line 

into smaller zones, with each zone powered by a separate energizer. 

NEVER EVER PUT 

MORE THAN ONE ENERGISER ON THE SAME WIRE.    THAT IS VERY DANGEROUS.

 

 

2 The Pulse indicator light is not flashing. 

 

3 The battery needs frequent replacement. 

If using a solar panel check that the solar panel is clean and is not damaged. Make sure 

the panel is positioned to receive maximum sunlight. If necessary, remove any objects or 

vegetation  that  might  be  casting  a  shadow  on  the  energizer.  Consider  using  a  larger 

capacity battery 

 

5. Maintenance   

Warning:  Other than changing  batteries,  there are no user-servicable parts.    If repair  is 

required please contact MGG 

.     

Fault 

Solution 

The 

Pulse 

indicator  light  is 

flashing,  but  the 

electric 

shock 

delivered  by  the 

fence is weak. 

Check that all connections in the fence and earth system are firm 

and secure. If necessary, clean away any corrosion. 

Check that the earth rod is pushed firmly into firm ground and is 

not rusty. Check that there is moisture in the ground. 

Check for faults in the fence-line caused by trees or vegetation. If 

necessary remove obstructions and mend the fence. 

Check that the energizer is adequate for the length of the fence. If 

Содержание EF-SRD12-1000A

Страница 1: ...1 ELECTRIC FENCING ENERGIZER USER MANUAL Model MGG EF SRD12 1000A For up to 25Km wire ...

Страница 2: ...2 Contents 1 Introduction 3 2 Important safety introduction 3 3 Specification 6 4 Installation guide 6 5 Maintenance 7 6 Guarantee 8 ...

Страница 3: ...t safety introduction WARNING Please read all instructions Do not touch a live fence Do not drench with water This product is for use in controlling livestock Any other use is prohibited Keep fence clear of weeds branches etc to avoid electrical shorts resulting in battery drainage Do not climb over through or under a multi wire electric fence Use a gate or a specially designed crossing point Do N...

Страница 4: ...s shall be constructed so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the non electrified wires The barbed wire and razor wire shall be earthed at regular intervals Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric fence at that point or a crossing by means of stiles At an...

Страница 5: ...lectric Animal Fence or the symbol shown The inscription shall be indelible inscribed on both sides of the warning sign and have a height of at least 25mm Ensure that all mains operated ancillary equipment connected to the electric animal fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the energizer Protection from the weat...

Страница 6: ...d out of reach of animals and children inside a protective fence if required If charging the battery using a solar panel the solar panel should face true north in the southern hemisphere and true south in the northern hemisphere positioned to get the maximum all day sun Mounting the energizer The energizer can be mounted directly onto a wooden post using appropriate screws to fit the slots on the ...

Страница 7: ... THAN ONE ENERGISER ON THE SAME WIRE THAT IS VERY DANGEROUS 2 The Pulse indicator light is not flashing 3 The battery needs frequent replacement If using a solar panel check that the solar panel is clean and is not damaged Make sure the panel is positioned to receive maximum sunlight If necessary remove any objects or vegetation that might be casting a shadow on the energizer Consider using a larg...

Страница 8: ... MGG for service The battery needs frequent replacement If using solar check that the solar panel is clean and is not damaged Make sure the panel is positioned to receive maximum sunlight If necessary remove any objects or vegetation that might be casting a shadow on the panel 6 Guarantee We grant a warranty of 24 months as standard starting from the date of the purchase invoice We will only perfo...

Страница 9: ...9 The animal completes the circuit and receives a shock Fence wire spacing guidelines For a good earth 3 earth rods are recommended 1m to 2m long and each 1m apart Black Red Battery Min 1m ...

Страница 10: ...rikeri New Zealand www mggproducts co nz email info mggproducts co nz The design and specification shall be subject to changes without prior notice The final interpretation right of this event is reserved by our company ...

Отзывы: