Use destination

Use destination

Item 904100   is used for:   general unclogging, for small gas, water and air systems tests, for loading expansion
boilers. 
The manufacturer declines all responsibility for damages caused from a wrong use of the machine. The machine does
not be for any reason wrongly settled. 
In that case the manufacturer declines all responsibility for the operation and security of the machine. 

Instructions

Instructions

FOR UNCLOGGING A DRAINAGE 
1.Put the pump to the wished pressure. We suggest you to  try with less pressure (~ 3 atm.) and to increase later in
the event the tube has not been unclogged. 
2. Insert the conical pad in the drainage to unclog, eventually using the bigger diameter pads for larger drainages
already enclosed in the equipment.
3. After that be sure that the drainages connected to the one to unclog are closed with something so that the water in
the tubes does not go out (Es. a wet rag),  open the express tap keeping pressed the pad in the drainage. 

TO TEST SYSTEMS 

 

1.Close the tap and  tight the screw without using other instruments. Please also close the slider tap.
2. close the express tap and tight the screw with the same here above precaution; open the

 

slider tap and put the

pump to the wished pressure. 
3. For the period relevant to the necessary time for test, remember to close the slider tap. In order to maintain the
system in pressure without leaving the pump in the  working area, MGF suggests to use  

HELP

  (Art.904400)  not

supplied in the pump equipment. 

FOR LOAD EXPANSION  BOILER VASES 
1. Connect the pump to the expansion vase to load and  execute operations 1. and 2. like in the previous operation. 

Attention

Attention

Use the pump only for its functions following general safety rules. Keep the machine far from children. Keep the
working place clean and with good light. 
Put   the   pump  in  a  way  as  that  loading  operation   can  take   place   in  a   safety   way.

  Avoid  loading  the  pump  on

disconnected or not horizontal surfaces.

Execute the  loading operations making sure that there is a good keeping of the handle. 

Do not work with greased

hands; if necessary, clean the hands before loading the pump.

 

During the loading, always help the return of the piston keeping well the handle.

 

Remember that the opening of the express drainage tap generates a reaction (repercussion) on the tube.

 

The intensity

of such reaction depends from the pressure to which it has been loaded the pump, but is in any case less than 20 N
(~2 Kg).

  Keep the tube strongly before opening the express drainage tap.

 

In any case, keep far strangers and

children. Never address the tube towards people, animals or things. 

The constructor declines responsibility for damages caused from the non respect of the destination use,