background image

Pulsar EXtreme C is only two units high (2U)

and fits perfectly in your network or telecom

bays.

Easy installation and integration

• Tower or 19”-rack models

• Complete installation kit

Pulsar EXtreme C is supplied with telescopic
rails and all the necessary hardware

• Quick start-up guide

• Easy connection to AC power.

UPScontrol remote display

Using UPScontrol, the

various UPS 

parameters are remotely

displayed.

MultiSlot expansion module 

This module provides three additional

communications slots and concentrates

the data from an installation comprising 

redundant UPSs

Communications slot 

Lets you add an SNMP, dry contact, etc.

communication card.

The cards make UPS

communication

totally independent.

For example, they

keep you informed

of UPS status when

the server is shut

down.

Individual management of

outlets with Powershare

TM

The programmable outlets

make it possible to save

battery power for the most

critical applications. They

may also be used to

remotely restart or reset a

faulty device without

interrupting the other

protected devices.

Flexibility and scalability

Advanced communications

Ease of use

ON/OFF

operation on battery

operation in ON-LINE mode

operation on bypass

status of
programmable
outlet no.1

lamp test or buzzer off 
forced transfer to and from 
bypass

UPS overload   

electronics fault

battery fault

press and hold to display
percent load

% battery backup time

Pulsar EXtreme C UPSs offer communications solutions and accessories for remote UPS control

and monitoring. 

Pulsar EXtreme  C can adapt easily to all your needs, today and tomorrow.

Comprehensive display 

and controls

2 communications ports

USB

communications port

RS232

communications port

status of
programmable
outlet no.2

Backup times from 6 minutes to

several hours

Pulsar EXtreme offers a standard backup

time of 6 minutes.

To ensure greater continuity of service, 

it is possible to:

• connect up to three Pulsar EXB battery 

extension modules to the UPS, without

interrupting the supply of power to the

protected applications;

• use the CLA module (long backup-time

charger) for very long backup times of up

to eight hours at full rated load. 

Feel free to contact us for details.

Hot-swappable batteries

Users can replace the batteries themselves

without having to shut down the protected

equipment.

Warranty and services

Pulsar EXtreme C is covered

by a two-year full 

warranty. 

The optional MGE

W extension

ensures user peace

of mind for three

years on site.

An RS232 and a USB port are available 

for easy connection of the UPS to the

server. It may be used for:

• 

personalization of Pulsar EXtreme C

by modifying the factory-set parameters

(output voltage, intervals between battery

tests, operation on bypass, etc.) via 

UPS-Driver software.

local or remote administration

(SNMP/WEB) of the UPS and the protected

servers, using Solution-Pac software.

Solution-Pac software

Solution-Pac may be used to:

• alert users;

• automatically shut down different 

servers in a heterogeneous environment;

• remotely supervise and control UPSs.

Pulsar EXtreme 1500 C + 3 Pulsar EXB
modules for 80 minutes of backup time
at full rated load .

Содержание Pulsar EXtreme C UPS 1000 VA

Страница 1: ...a climber who snaps on a biner for a safe ascension you can count on Pulsar EXtreme C to protect you no matter what Pulsar EXtreme C offers the best in power protection plus the C for compact design High performance and reliability High availability Advanced communications Ease of use Flexibility and scalability www mgeups com Maximum security for your servers PBXs and network equipment in minimum...

Страница 2: ... disturbances on the distribution system the waveform is regenerated via the AC to DC then DC to AC conversion process High performance battery charger The Pulsar EXtreme battery charger reduces battery recharge time 80 backup time recovered in two hours increases the service life of the battery by taking into account manufacturer parameters and battery aging protects the battery against damage ca...

Страница 3: ...essories for remote UPS control and monitoring Pulsar EXtreme C can adapt easily to all your needs today and tomorrow Comprehensive display and controls 2 communications ports USB communications port RS232 communications port status of programmable outlet no 2 Backup times from 6 minutes to several hours Pulsar EXtreme offers a standard backup time of 6 minutes To ensure greater continuity of serv...

Страница 4: ...t current A 25 29 29 Overload capacity Online mode 110 permanent 130 12s 130 1 5s Batteries Backup time 100 Pn 50 Pn 100 Pn 50 Pn 100 Pn 50 Pn Standard 7 14 7 17 6 19 Pulsar EXtreme C 1 Pulsar EXB 24 47 27 59 24 79 Pulsar EXtreme C 2 Pulsar EXB 41 82 47 93 43 119 Pulsar EXtreme C 3 Pulsar EXB 53 124 64 136 62 168 Automatic battery test Yes at regular intervals without risk of interrupting protecte...