24 – CS 300 RM Gate Controls / Rev. B 1.0
Dimensions
215 x 275 x 190 mm
Housing:
Installation:
Mount vertically on a wall; minimum installati
-
on height: 1,100 mm
Supply voltage:
230 V/AC 50/60Hz
Switching current:
max. 4A
Switching capacity:
max. 920 VA
Internal fuse:
4AT
Fuse protection:
Type K 10A fuse
Intrinsic consumption
max. 250 mA
of control unit
Control voltage:
24 V DC; maximum of 250 mA; protected by a
self-resetting fuse for external sensors. All control
voltage inputs are separated galvanically from the
mains power supply.
Control inputs:
24 V DC; all inputs must be connected such
that they are potential-free. The minimum signal
duration for input control commands is > 100 ms.
Control outputs:
24 V DC; max. 250 mA
Safety circuit /
All input connections MUST be potential-free
Emergency off:
if the safety circuit is interrupted, no further door
operator movement is possible – not even in
deadman mode
Input for safety
For electrical safety edge protection strips with
edge strip:
8,2 k
W
terminating resistance and for dynamic
optical systems.
Relay outputs:
If inductive loads are connected (e.g. further
relays or brakes), these must be equipped with
suitable interference suppression (recovery diode,
varistors or RC circuits). Normally-open potential-
free contact; minimum of 10 mA; maximum of
230 V AC / 4 A.
Once contacts have been used in power circuits
they can no longer be used for low currents.
Temperature range:
In operation:
-10 °C …+45 °C
In storage:
-25 °C ... +70 °C
Air humidity:
Up to 80%, non condensing
Vibration:
Low vibration mounting, e.g. on a masonry wall
Protection category:
IP 65
Weight:
Approx. 1.8 kg
11. Technical data