VU Meter
The VU meter is used to calibrate the amplitude of the signal you are putting into the phone line. The
MFJ-624DM meter is calibrated to –10 dBm. This means that if the meter reads 100% (zero VU), it is
actually –10dBm. The VU meter reads the level of the telephone line. Factory adjustment was done
according to ta 600 ohm standard signal (0 dBm). Telephone impedances vary in the U.S. anywhere
from 300 ohms to 900 ohms. Therefore, the meter readings will vary slightly from one phone system to
another.
Adjust the Receiver Gain control until the meter reads somewhere around 0 VU (100%) on voice peaks.
Note: Telephone company regulations prohibit you from putting any signal into
the phone line with a higher level than –9dBm. Normally, no more than –15 to –
10 dBm is necessary for good volume.