Meter Calibration (cont.) 

 

8.  With the 

300/30 Watts

 button pushed 

out 

for the 6 Watt reflected scale, Transmit 

1 Watt as indicated on the reference meter.  Adjust the LO REF trim pot to set the 
reflected power scale to 1 Watt. 

 

9.  SWR requires no calibration. 

 

10. Repeat each calibration for each frequency if needed until the meter has the 

correct readings on each frequency.  

 
 
 

 
 
 
 
 
 
 
 

 

Figure 1

: Test Setup

 

 
 

 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 2

: PCB Layout and Trim Pot Location 

 

 

 

VHF/UHF 