MFJ MFJ-817C Скачать руководство пользователя страница 1

MFJ-817C Deluxe VHF/UHF True Peak Reading SWR/Wattmeter 

Instruction Manual

 

MFJ-817C Deluxe VHF/UHF True Peak Reading 

SWR/Wattmeter 

 

Introduction 

 
The MFJ-817C is a true peak reading SWR/Wattmeter designed to operate on 
144/220/440 MHz.  This meter uses our 

TrueActive

 peak reading circuit to read true 

peak/average forward and reflected power and SWR simultaneously.  It has 300/30 Watts 
forward and 60/6 Watts reflected power scales.  The MFJ-817C utilizes a large 
illuminated three-inch Cross-Needle meter to read the SWR from 1:1 to 

 

Installation 

 

1.  Connect your transmitter to the connector on the back of the unit labeled 

TRANSMITTER and your antenna to the connector labeled ANTENNA.  It is 
important that you use good quality coax and properly installed connectors. 

 

2.  The MFJ-817C has a 

TrueActive

 

peak reading circuit that requires a DC power 

supply such as the MFJ-1312B in order to function.  A 9 VDC may also be 
installed inside the meter with a battery clip that is included. The rear panel 
accepts a 2.1 mm coaxial plug with the center conductor positive (+) and the 
sleeve negative (-).  The negative lead is grounded inside the meter.  There is no 
need to disconnect the battery when using external power. 

 

3.  An internal lamp backlights the meter scale.  The lamp circuit requires 12 VDC 

and will not illuminate with the 9 VDC battery alone. 

 

4.  To measure the power output capability of a transmitter/amplifier you should 

connect a quality 50-ohm dummy load to the ANTENNA connector of the MFJ-
817C. 

 

NOTE: 
The wattmeter must have a power source in order to function.  A nine -volt 
battery may be installed in the compartment on the rear panel, or an external 
12 VDC source, such as the optional MFJ-1312D power supply, may be used.

 

IMPORTANT: 

Please read entire manual before attempting to operate this equipment.  This 
unit does not provide a dc or low frequency earth ground.  A separate wire 
should be connected from the station ground bus to an electric ground.  Do 
not place any non-coaxial feed wires near metallic or RF sensitive devices. 