background image

RECORDING MESSAGES WITHIN MESSAGES

A  special  feature  of  the  MFJ-486  is  that  you  may  record  any  of  the  messages  within  any  other
message. To accomplish this you key in the message number of the message to be inserted at the
point which you want to call it in step 4 above. For example, if you wanted to insert message A3
inside message A2 you would key in didahdidididahdah at the point in message A2 you wanted A3
to play. If you wanted message E2 to play in A2 you would instead key in didididahdahdah at the
point where you wanted E2 to play. Note that when calling a memory location, there is no space in
the address.

AUTOMATIC CONTEST NUMBER

Messages A5 and E5 are reserved for a four digit contest number. Sending message A5 will send
the number stored in this location. Sending message E5 will increment the number and then send
it. Recording a number in either location will store the number in both locations. If you attempt to
store any morse code except numbers in these messages, the computer will change the code to 0.

RANDOM CODE GENERATOR

The MFJ-486 is equipped with a Random Code Generator which can be used to learn code and in-
crease code speed. It has two basic modes of operation- character sets and English messages. In
order to operate the character set generator:

1. Put RANDOM CODE switch on with the REPEAT switch off.

2. If you want all the Morse characters including punctuation put the RECORD/EDIT switch out. If

you do not wish to use punctuation, put the RECORD/EDIT switch in.

3. The  AUTOMATIC  WORD  space  switch  on  will  result  in  groups  of  five  characters.  AUTOMATIC

WORD space switch off gives random group length from 1 to 8 characters.

4. Press  a message  switch  and  the  random  code  will  begin.  It  can  be  stopped  at any  time  with

the DOT paddle and restarted with the DASH paddle.

5. The DELAY pot can be used to increase the spacing while using the RANDOM CODE GENERA-

TOR. This allows you to send practice code in the Farnsworth Method.

6. Messages  E1  through  E5  are  always  constant.  Messages  A1  through  A5  will  repeat  until  the

power is turned off and then back on. When the power is turned off and then on, messages A1
through A5 will be changed.

In order to operate the RANDOM CODE GENERATOR in the English message mode:

1. Put the RANDOM CODE switch on and the REPEAT switch on.

2. Put the RECORD switch on.

3. Press  one  of  the  momentary  message  switches  and  a  random  English  message  will  begin.  It

can be stopped at any point with the DOT paddle and will resume with the DASH paddle.

4. Items 5 & 6 above applies equally to the English messages.

Содержание GRANDMASTER II

Страница 1: ...MFJ GRANDMASTER II CONTEST MEMORY KEYER MFJ 486...

Страница 2: ...hode and solid state transmitters For grid block keying use the Grid Block keying output For cathode keyed and solid state transmitters use the Direct keying output Try both outputs if you are uncerta...

Страница 3: ...djust key ing speed The Speed Control Potentiometer will adjust the keying speed over a 5 to 1 ratio The Speed Set Switch will make the current speed control setting equal to 20 WPM For example if the...

Страница 4: ...MEMORY CLEAR The entire memory may be cleared In order to do this you must start with the power off and all pushbutton switches in the out or off position Press the A1 and A2 switches simultaneously a...

Страница 5: ...ace between two otherwise perfectly valid characters You may test this feature by keying in seven consecutive dots while in the Add mode of the CW Editor 1 To record a message first press the RECORD E...

Страница 6: ...ing the keyer in the Automatic Word Space mode you must send from the key paddles with correct character and word spacing Improper spacing will not be accepted by the 486 15 Press the CONTINUE button...

Страница 7: ...n on to signify that this address has been selected 4 Press the ERASE switch The DELAY EDIT LED should blink to signify that the operation is being performed 5 Press the ADD switch The DELAY EDIT LED...

Страница 8: ...e way CCW For the maximum delay set the DELAY control all the way CW This should result in a maximum delay of approximately 3 minutes This allows you to use the keyer as a beacon If repeating is not d...

Страница 9: ...odes of operation character sets and English messages In order to operate the character set generator 1 Put RANDOM CODE switch on with the REPEAT switch off 2 If you want all the Morse characters incl...

Отзывы: