MFJ CW-Elmer MFJ-419 Скачать руководство пользователя страница 13

MFJ-914 CW-Elmer 

Version 0 

13 

2022 MFJ Enterprises, Inc.

 

selected WPM rate, and be able to do so repeatedly with minimal 
variance. For a given WPM rate, DIT and DAH are assigned an 
ideal  duration,  calculated  by  DIT(mS)  =  1200/WPM.  For 
example,  at  15WPM,  the  duration  for  a  DIT  is  80mS,  while  a 
DAH will be 240mS in duration.  

The top line of the display shows the target (ideal) time in mS for 
a DIT or DAH, depending on selected exercise. This is followed 
on the same line by the measured time the key was pressed.  

The lower line displays this information graphically, with a target 
shown as ” 

 < > + “. In this line, the brackets “ < > ” represent the 

target time for DITs or DAHs, with shorter times are to the right 
(+), and longer times to the left (

).  

A  marker  “  *  ”  indicates  the  measured  time  of  key  press.  The 
objective is to time your key press so the marker falls inside the 
brackets,  as  “  <*>  “.  If  the  marker  is  to  the  right,  hold  the  key 
longer; if on the left, shorten the hold time. Holding the key down 
longer than 2 seconds will exit the exercise and return control to 
the MAIN MENU. 

 

dit^dah Pause   

(Intra-Character Pause) 

 

A^B Pause 

  

(Character Pause) 

 

WORD^WORD Pause   (Word Pause) 

Just  as  important,  and  perhaps  more  difficult  to master,  are  the 
pauses  that  occur  between  DITs  and  DAHs  within  a  character, 
between characters in a word, and between words. Proper timing 
of these pauses could be the difference between “Y” and “TAT”, 
or between “A NICE HOUSE” and “AN ICE HOUSE”, each with 
totally different meanings, the first being a pleasant dwelling, the 
second  an  igloo!  To  practice  these  exercises,  the  key  must  be 
pressed two times. CW

ELMER measures the pause, or key UP, 

time between presses. The first press will make a low tone and 
the second press will make a high tone. 

The  duration  of  each  key  press  is  not  relevant;  I  suggest 
practicing  with  letters  “I”  (..),  “M”  (

‐‐

),  “A”  (.

),  and  “N”  (

.)  to 

develop a real

world feel.  

The top line of the display shows the target (ideal) time in mS for 
an  IntraChar  Pause,  Character  Pause,  or  Word  Pause, 
depending  on  selected  exercise.  This  is  followed  on  the  same 
line  by  the  measured  time  the  key  was  released  between 
presses.  

The lower line displays this information graphically, with a target 
shown as ” 

 < > + “. In this line, the brackets “ < > ” represent the 

Содержание CW-Elmer MFJ-419

Страница 1: ......

Страница 2: ......

Страница 3: ...CODES 11 USB READER 11 EXERCISE MENU 12 SETTING MENU 14 SET WPM 14 TIMING MODE 15 CHARACTER SET 15 SIDETONE 15 ABOUT 15 Resetting the EEPROM 15 Battery Installation and Replacement 16 Firmware Update...

Страница 4: ...in code and in text The Analyze setting will display your speed and timing to help you to send better code The Receive mode of the MFJ 419 will send you code to help you to learn the characters It ca...

Страница 5: ...ng 5 The KEY button can be used for slow practice but is most convenient for selecting modes and settings when a hand key is not available or inconvenient Follow the instructions in the MAIN MENU sect...

Страница 6: ...is why the MFJ 419 CW ELMER is the ideal tool for learning the code It provides a wide variety of practice sessions all sent in truly random fashion and with high quality Unlike tapes which you quick...

Страница 7: ...Note when exiting out of any of the functions you return to this MAIN MENU Send Receive Exercises Settings SEND MENU Send mode is the most like a conventional Code Practice Oscillator Press the key a...

Страница 8: ...then interprets the keying and displays the characters with correct timing and pauses If a character is not recognized the display will say undefined on the bottom line The top line displays the chara...

Страница 9: ...E STATS Tone xxxmS DAH is less than this time Screen 6 DAH Time xxxx total DHA time DAH Count xx number of DAHs analyzed Screen 7 DAH Target xxx target length DAH Avrage xxx average DAH length Screen...

Страница 10: ...OW Time xxxx total EOW time EOW Count xx number of EOWs analyzed Screen 15 EOW Target xxx target length EOW Avrage xxx average EOW length Screen 16 EOW Max xxx maximum EOW length measured EOW Min xxx...

Страница 11: ...random group of code KEY to EXIT USB READER Text via USB KEY to Exit Practice listening for more real life words and sentences is available using the USB Reader function This function allows you to se...

Страница 12: ...s it fills up the buffer Pressing the KEY button for about 1 second will pause the sending and pressing the KEY button for 2 seconds will exit the USB Sending mode to the MAIN MENU The terminal will a...

Страница 13: ...xercise and return control to the MAIN MENU dit dah Pause Intra Character Pause A B Pause Character Pause WORD WORD Pause Word Pause Just as important and perhaps more difficult to master are the paus...

Страница 14: ...exit the exercise and return control to the MAIN MENU Cancel Cancel returns you to the MAIN MENU SETTING MENU The SETTING menu is a group of settings that may be altered to make CW ELMER operate accor...

Страница 15: ...letters numbers and punctuation This menu offers you that choice of character group ABCD Alpha only default ABCD 1234 Alpha and Numbers ABCD 1234 Alpha Numbers and Punctuation Cancel SIDETONE CW Pitch...

Страница 16: ...d the firmware update from MFJ 3 Plug a USB cable into your computer and the MFJ 419 The Computer should find the drivers automatically but if not they can be obtained from the FTDI web site https ftd...

Страница 17: ...display Done Uploading in the IDE While it is uploading the MFJ 419 will stop the display then when finished start up and run as when powered on There may be a message indicating low memory available...

Страница 18: ...B I P W C J Q X D K R Y E L S Z F M T G N U Numbers 0 3 6 9 1 4 7 2 5 8 Punctuation Period or Stop Comma Exclamation Pt Double Dash Left Parenthesis Right Parenthesis Dash Colon Question Mark Apostro...

Страница 19: ...Receiver CPY Copy RIG Station equipment CQ Calling any station RITE Right CUL See you later RST Readability strength tone rpt CU See you SIGS Signals DE From SKED Schedule DEG Degree STN Station DX Di...

Страница 20: ...ill call again at wait QRZ Who is calling me I am QSB Your signal is fading QSD Your keying is defective QSK I can hear you between my signals QSL I am acknowledging receipt QSU Reply on this frequenc...

Страница 21: ...inally developed by David Duncan K7DUN With that in mind the firmware can be updated or modified the same way as an Arduino Nano and programmed through the USB port using the standard Arduino IDE The...

Страница 22: ...MFJ 914 CW Elmer Version 0 22 2022 MFJ Enterprises Inc Notes...

Страница 23: ...rms are satisfied MFJ must receive the original parts you wish to replace your proof of purchase and a personal check cashiers check or money order must be provided to cover postage and handling Posta...

Страница 24: ......

Отзывы: