INSTALLATION

 

 

1.  The unit can be located at any convenient location, as long as it is not 

exposed to moisture. It should be grounded to the station ground, and 
preferably powered from a separate wall adaptor.  

 

2.  Connect your antennas to the SO-239 coax connectors numbered 1-4. 

Note which antenna is connected to each connector. 

 

3.  Connect your transceivers to the SO-239 coax connectors labeled A-D.  

Note which transceiver is connected to each connector. 

 

4.  Connect a feedline from the TRANSMITTER COMMON connector to the 

ANTENNA COMMON connector. 

 

5.  Connect the station ground to the GROUND connector. 

 

6.  If your Transceiver is equipped with a 12VDC accessory jack, you may 

connect it to the Antenna/Transceiver Switch using a RCA plug so when 
your Transceiver is off, all inputs are automatically grounded.  
You may also connect the Antenna/Transceiver Switch to your power 
supply using a RCA plug, so when you turn off the power supply, all inputs 
are automatically grounded. 

 

7.  If you are using the MFJ-4724RC Remote Control, connect the RJ-45 

modular jack from the ANTENNA jack on the Remote Control to the 
ANTENNA REMOTE jack on the back of the unit and connect the RJ-45 
modular jack from the TRANSCIEVER jack on the Remote Control to the 
TRANSCIEVER REMOTE jack on the back of the unit using a CAT-5 
cable. 

 

8.   If your Transceiver is equipped with a 12VDC accessory jack, you may 

connect it to the Remote Control using a RCA plug so when your 
Transceiver is off, all inputs are automatically grounded. 

 

9.  An additional remote mount option is to remove the cover, remove the 

knob-shaft coupler using an Allen wrench and remove the knob.  Now, the 
unit can be placed facedown if desired. 

 

 
 
 
 
 
 

Содержание MFJ-4724

Страница 1: ... unused inputs are grounded You can connect a sense line to your transceiver so when it s off all inputs are automatically grounded The MFJ 4724 will work well in nearly any system requiring switching of coaxial lines especially those requiring good quality 50 ohm RF switches so you can select one of four radios to one feedline or one of four antennas to a radio MFJ 4724 Desktop Remote Antenna Swi...

Страница 2: ... 3 5 1 0 1 0 1 0 1 0 7 1 1 0 1 0 1 0 1 0 14 1 1 1 1 0 1 0 1 1 21 0 1 1 1 1 1 1 1 1 29 7 1 1 1 1 1 1 1 1 54 0 1 8 1 5 1 5 1 8 150 0 1 7 1 5 1 5 1 7 Table 2 SWR for each Transceiver Connection on Selected Frequencies Tables 1 2 show the SWR for each Antenna and Transceiver Connection To determine the best Antenna and Transceiver combination for your particular frequency simply choose the connections...

Страница 3: ...iver Switch using a RCA plug so when your Transceiver is off all inputs are automatically grounded You may also connect the Antenna Transceiver Switch to your power supply using a RCA plug so when you turn off the power supply all inputs are automatically grounded 7 If you are using the MFJ 4724RC Remote Control connect the RJ 45 modular jack from the ANTENNA jack on the Remote Control to the ANTE...

Страница 4: ...d on the front of the control panel and a space is provided to pencil in the designation for each antenna Once the antenna or transmitter is selected you may transmit into the selected antenna 3 If you are using the MFJ 4724RC Remote Control turn the Selector Knob on the MFJ 4724 to the OFF Remote position a Connect the 2 1mm plug DC power supply and the RJ 45 modular jack to the Remote Control b ...

Страница 5: ... 323 0549 or the MFJ Factory at 662 323 5869 You will be best helped if you have your unit manual and all information on your station handy so you can answer any questions the technicians may ask You can also send questions by mail to MFJ Enterprises Inc 300 Industrial Park Road Starkville MS 39759 by Facsimile FAX to 662 323 6551 or by email to techinfo mfjenterprises com Send a complete descript...

Отзывы: