Note: all dimensions are accurate to ± 3% and all weights are accurate to ± 5%

RS8ER

RS10ER

No. of persons

8

10

Length (cm)

350

400

Width (cm)

190

190

Height (cm)

56

56

Tube Diameter (cm)    Front

                                      Rear

23

23

35

35

Floor Thickness (cm)

12

12

Working Pressure

0.2 bar

0.2 bar

Number of Chambers

3 inc. floor

3 inc. floor

Capacity (kg)

820

950

Air Requirements (ltr)

1815

2000

Pack size (cm)

88x50x33

140x50x35

Weight (kg)

35

38

Recommended regulator

8 bar

8 bar

Technical Data

Содержание RS10ER

Страница 1: ...1 MFC International 2018 Product Manual Evacuation Raft...

Страница 2: ...ational Instructions Packing Storage Maintenance Test Procedures Repairs 3 4 5 6 8 8 9 10 WARNING Carefully read this manual before operating NOTICE The manufacturer takes no responsibility for the co...

Страница 3: ...h cm 350 400 Width cm 190 190 Height cm 56 56 Tube Diameter cm Front Rear 23 23 35 35 Floor Thickness cm 12 12 Working Pressure 0 2 bar 0 2 bar Number of Chambers 3 inc floor 3 inc floor Capacity kg 8...

Страница 4: ...4 MFC International 2018 Parts List 9 10 11 16 6 14 7 1 3 7 11 4 11 2 3 15 5 8 8 2 8 17 14 4 15 5 www m fcsurvival c om www m fcsurvival c om www m fcsurvival c om 7 7 7...

Страница 5: ...lyester 316 s s D ring 10 D Ring Patch Hypalon coated polyester 316 s s D ring 11 Reflective Strips 50mm Reflexite 12 Logo Label White vinyl digitally printed 13 Capacity Label White vinyl digitally p...

Страница 6: ...ost every operational scenario will have different hazards and risks which can only be properly assessed at and during an operational rescue recovery WARNING During use on water mud or suspect surface...

Страница 7: ...s CAUTION Avoid contact with sharp or abrasive objects as they may puncture the fabric causing a loss of buoyancy 2 8 Carrying handles The Evacuation Raft should only be carried by the moulded handles...

Страница 8: ...The following is a recommended regime for maintenance test 2 QUARTERLY 2 1 Check control equipment as per relevant manual 2 2 Inflate Evacuation Raft to working pressure 2 3 Check audible relief valve...

Страница 9: ...2 Allow the Evacuation Raft to become as dry as possible before packing 3 Lay the Raft on a clean debris free area 4 Deflate the Evacuation Raft This is achieved by depressing the central spindle in a...

Страница 10: ...ired by the application of a small repair patch b Repairs that should be carried out by MFC will be the more serious kind such as damaged valves badly torn fabric either on the side walls or the flat...

Страница 11: ...11 MFC International 2018...

Страница 12: ...national Naval Yard Tonypandy Rhondda Cynon Taff CF40 1JS T 44 0 1443 433 075 F 44 0 1443 420 448 sales mfc international com www mfc international com A Respirex International Limited Group Company S...

Отзывы: