Pneumatic table stapler
TH 210
Page:
9
Change:
02/2019
ET
598
Page 9 of 12 21.02.19 P:\Technik\TH_THE_210\Bedienungsanleitung\Englisch\BA TH 210 02_2019_EN.docx
15.1 No stapling occurred or the staple wasn't
fully
bent, or it
remains
in the stapling device
Fault
Cause
Remedy
No pressure indication
Shut-off valve closed.
Open the shut-off valve.
Pressure not set.
Set the pressure with the pusher
adjustment knob.
Pressure gauge defective.
Replace pressure gauge.
Low flow rate (operating pressure
collapses during air consumption)
Filter cartridge is dirty.
Replace the filter cartridge.
Constriction between main valve
and maintenance unit
Check the lines.
Pressure rises above set operating
pressure
Valve disc at the sealing seat
defective.
Contact the manufacturer
Audible blow-off at the control
knob
Valve seat defective.
Contact the manufacturer
Audible blow-off at the drain plug
Drain plug leaking.
Tighten or replace.
Feed movement not guaranteed.
Air pressure too low.
With stapling 4 - 6 bar overpressure.
Check hoses and valves, and ensure
a sufficient air supply.
Air cleanliness inadequate
Compressed air
Connect a maintenance unit upstream
consisting of a pressure regulator and
water separator.
Staple is jammed in the stapling
head and is not preformed.
Compressed air
Air pressure too low.
Stapling device operated too quickly.
16
Technical data/versions
Drive
pneumatic
Operating pressure
4-5 bar
Distance between insert
staplers
min 45 mm to max 200 mm
Number of insert staplers
1 to max. 5 (2 standard)
Air consumption/stapling
approx. 0.06 NL per cylinder and stapling
Staple type
66/6 galvanized and 66/8 galvanized
Stapler type
Insert stapler 105
Number of staples
max. 210
Depth x width x height
approx. 285 mm x 270 mm x 220 mm (standard)
Total weight
approx. 5.2 kg (2 insert staplers)
Counter
optional