background image

 

         

 

 
 
 
 

BENCH PRESS 10 Tn 20 Tn 

 AIR PUMP 

 

“ECZ01113” “ECZ02013” 

 

 

 
 
 
 

LARZEP,

 

S.A.

 

 

 

LARZEP

 

AUSTRALIA

 

PTY.

 

LTD.

        

LARZEP

 

AUSTRALIA

 

PTY.

 

LTD.

 

Avenida

 

Urtiaga,

 

6

 

  

139

 

Wedgewood

 

Road,

  

      

49A

 

Sustainable

 

Avenue

 

48269

 

MALLABIA,

 

SPAIN

 

HALLAM,

 

VIC.

 

3803

 

AUSTRALIA

       

BIBRA

 

LAKE,

 

WA

 

6163

 

AUSTRALIA

 

Tel.

  

+34

  

943

 

171200

    

Tel.

  

+61

 

(3)

 

9796

 

3744

   

 

Tel.

 

+61

 

(8)

 

9418

 

4988

      

Fax.

 

+34

  

943

 

174166

   

Fax.

 

+61

 

(3)

 

9796

 

5964

   

 

Fax.

 

+61

 

(8)

 

9418

 

2644

 

e

mail:

 

[email protected]

 

e

mail:

 

[email protected]

    

e

mail:

 

[email protected]

 

www.larzep.com

 

           

www.larzep.com.au

 

 

 

www.larzep.com.au

 

Содержание ECZ01113

Страница 1: ... Road 49A Sustainable Avenue 48269 MALLABIA SPAIN HALLAM VIC 3803 AUSTRALIA BIBRA LAKE WA 6163 AUSTRALIA Tel 34 943 171200 Tel 61 3 9796 3744 Tel 61 8 9418 4988 Fax 34 943 174166 Fax 61 3 9796 5964 Fax 61 8 9418 2644 e mail sales larzep com e mail sales larzep com au e mail sales larzep com au www larzep com www larzep com au www larzep com au ...

Страница 2: ...ny air from the hydraulic circuit by opening the pump s relief valve placing the pump with its head down and pumping several times Do not operate hydraulic equipment near open flame explosives sources of intense heat or any other hazard which could cause a fire or the damage equipment The hydraulic equipment should not be exposed to temperatures grater than 60ºC when in use or when stored When cho...

Страница 3: ...and it maintains the pressure loosen the pedal In order to start the equipments it is necessary to connect the pump to the compressed air connection at 6 Bar pressure In order to stop the cylinders advance release the pedal or disconnect the compressed air feeding For a new beginning it will be necessary to unblock the device and push the pedal in pump position 3 3 SAFETY PREVENTIVE ACTIONS AGAINS...

Страница 4: ...uge adaptor with 3 8 BSP thread PNEUMATIC CONNECTION 1 Connect the pedal to the compressed air connection 2 Ensure that the pedal is not pushed CHECKING THE RIGHT OPERATION OF ALL DEVICES AND MECHANISM 1º Select the working maximum pressure 2º Put the feet in the pedal 3º Push the pump position 4º Check the cylinder advances 5º Check that the cylinder piston goes back pushed by the internal spring...

Страница 5: ... the retainer Directional valve damaged 5 Replace the valve Cylinders body damaged 6 Repair the body of the cylinder Pneumatic problem 7 Check the installation 2 The cylinder does not reach pressures Pressure relief valve unrated 8 Rate the valve Cylinder pressure retainer damaged See Solution 4 Cylinders body damaged See Solution 6 3 The cylinder does not maintain pressure Cylinder pressure retai...

Страница 6: ...6 INSTRUCTION MANUAL Bench Press with Air Pump 8 DECLARATION OF CONFORMITY ...

Страница 7: ...7 INSTRUCTION MANUAL Bench Press with Air Pump ...

Страница 8: ...8 INSTRUCTION MANUAL Bench Press with Air Pump JUEGO DE RECAMIBOS ...

Страница 9: ...9 INSTRUCTION MANUAL Bench Press with Air Pump ...