Pneumatic table stapler
TH 210
Page:
6
Change:
02/2019
ET
598
Page 6 of 12 21.02.19 P:\Technik\TH_THE_210\Bedienungsanleitung\Englisch\BA TH 210 02_2019_EN.docx
10
Maintenance and care
CAUTION!
Before performing any maintenance work, the compressed air supply must
be disconnected.
Any kind of alteration to the stapling device (e.g. drill holes) shall only be permitted
with a prior consent and written permission of the manufacturer.
the manipulations on the safety device(s) are forbidden!
In order to maintain the operational readiness and function of the stapling device, it must be regularly
checked and cleaned by the operator or by qualified personnel.
Check area
Activity / check
D
W
M
Y
Area
Stapling area and environment
cleaning
Complete stapling device
Stapling device
check / clean
Stapling area
Stapling device
Clean and
lubricate lightly
Loading area
check / clean
Pneumatic hoses, leak tightness,
damages
check
Pneumatics
Screw connections for tightness
check
Filter regulator
Cleaning/
draining
T = daily / W = weekly / M = monthly (6M = every 6 months) / J = yearly
Insert stapler:
After about 10,000 staple cycles operations, lubricate the insert stapler
with a few drops of thin oil and remove excess oil as shown in the
adjacent illustration.
The stapling device does not require a great deal of care, but should be
cleaned and maintained on a regular basis. Soiling should be removed
directly by the operator after the machining processes.
Adequate care will help to permanently keep the stapling device in
a functionally correct state. The stapling device should be cleaned thoroughly at least once a
week.
No aggressive cleaning agents or solvents (could damage seals),
or even sandpaper may be used for cleaning.
The cleaning with compressed air should also be avoided, since this could transport dirt particles
into the seals and damage them.
Do not use linting cleaning wool for cleaning work.
Oi
l