ULTRA XP OPERATING INSTRUCTIONS
29
2. Insert the five exposed conductors into the five cable holes in a Phoenix 5-pin female cable mount connector. Use the
following wiring scheme.
3. Secure the conductors by tightening the five screws in the Phoenix cable mount connector. Screws should be torqued to
5–6 Nm(4.4–5.3 In-Lbs).
CAUTION:
Screws should not be inserted into the Phoenix connector while the connector rests in a mating
plug. Doing so will damage the contacts. During assembly, the Phoenix connector should only be held in place
externally.
4. If the other (EN3) end of the cable has not been stripped, strip the outer shielding 1 inch and then strip the black, red,
blue, and white wires 0.275 inch.
5. Disassemble the EN3 5-pin female connector and feed the stripped cable through the boot, cable clamp housing, and
coupling ring.
Pin Destinations for Phoenix 5-Pin Female Cable Mount Connector
EN3 5-Pin Female Cable Mount Connector, Assembled (Left), Disassembled (Right)
Pin 1
Black
48 V DC (–)
Pin 2
Red
48 V DC (+)
Pin 3
Shield drain
Audio shield
Pin 4
Blue
Audio (–)
Pin 5
White
Audio (+)
Tighten screws
Cable clamp
housing
Boot
Coupling
ring
Cord
connector