Meyer Sound UMS-1P Скачать руководство пользователя страница 6

Looping Audio Input Module

This standard module uses a balanced,
female XLR connector for audio input
and a male XLR loop connector to inter-
connect multiple loudspeakers. The
audio input connector is hardwired with
pin 2 hot to comply with audio industry
standards. The loop connector, wired in
parallel to the audio input, transmits
the input signal even if the UMS-1P is
turned off for any reason.

Looping Audio Input Module

Looping, Polarity, and
Attenuating Audio Input
Module

This module has a balanced, female XLR
audio input connector, a male XLR loop
connector, an input polarity switch, and
a level attenuator knob. The input polar-
ity switch offers a convenient method of
reversing the phase of the loudspeaker.
When the input polarity switch is in the
up (+) position, pin 2 is hot relative to
pin 3, resulting in a positive pressure
wave when a positive signal is applied
to pin 2. When the switch is down (-),
pin 3 is hot relative to pin 2, resulting
in a positive pressure wave when a posi-
tive signal is applied to pin 3. The level
attenuator knob operates between 0 dB
(no level attenuation) in a fully clock-
wise position to -18dB in a fully coun-
terclockwise position.

Remote Monitoring System

The UMS-1P can be equipped to operate
with the Remote Monitoring System
(RMS) network and software application.
RMS displays signal and power levels,
driver status, limiter activity, the state
of the polarity switch, attenuator level,
and amplifier temperature for all loud-
speakers in the network on a Windows-
based PC. RMS can also be configured to
enable loudspeaker muting. RMS is an
excellent field diagnostic tool that
removes the guesswork from trou-
bleshooting during a performance.

All Meyer Sound loudspeakers with RMS
can be integrated on the same network.
Installing an RMS module requires only
a Phillips screwdriver. Contact Meyer
Sound for more information about RMS.

6

Amplification and Limiting

Each of the MS-410 drivers in the UMS-
1P is powered by one channel of a pro-
prietary Meyer Sound amplifier utilizing
complementary power MOSFET output
stages (class AB, bridged, 225 Wrms/ch
burst). The UMS-1P employs two sepa-
rate methods of limiting: Excursion
Limiting which protects the drivers from
over excursion and Sub Channel Limiting
which prevents the drivers from damage
due to thermal overload.

Limiter activity for the Excursion and
Sub channel is indicated by two yellow

Limit LEDs on the rear panel (the EXC.
Limit LED is above the SUB Limit LED).
See page 11 for a diagram of the user
panel.

The UMS-1P performs within its acoustical
specifications and operates at a nomal
temperature if the limit LEDs are on for
no longer than two seconds, and off for
at least one second. If either LED
remains on for longer than three seconds,
that channel will operate with these
characteristics:

• Increasing the input level will not

increase the volume.

• The system distorts due to clipping

and nonlinear driver operation.

While the UMS-1P limiters fully protect
the system under overload conditions
and exhibit smooth sonic characteris-
tics; we recommend that you do not
intentionally drive the UMS-1P into con-
tinuous limiting to attain compression
effects.

For applications where large amounts of
compression are required, we recom-
mend using an outboard compressor/
limiter for greater control of limit and
compressor effects.

AMPLIFICATION, LIMITING, AND COOLING SYSTEMS

Loop 

Input 

On / Temp.

Limit

Earth /
Chassis 

Case

220k 

GND 
Circuit

1
2
3

1
2
3

10k 

Ω 

Balanced

+

-

 Looping Audio Input

Network

Service

Wink Reset Activity

R e m o t e     M o n i t o r     S y s t e m

230

115

+

-

Polarity 

Loop 

Input 

On / Temp.

Limit

Attn dB

-

18

-

15

-

12

-

6

-

3

-

9

0

Earth /
Chassis 

Case

220k 

GND 
Circuit

1
2
3

1
2
3

10k 

Ω 

Balanced

+

-

 Looping Polarity & Attn. Audio Input

!

AC Input 115 / 230V

~

50-60Hz  3A MAX

AC Loop Output 115 / 230V

~

50-60Hz  15A MAX

Class 1 Wiring       

SET VOLTAGE BEFORE APPLYING POWER
RISK OF FIRE REPLACE WITH F3.15A - 250V FUSE

Meyer Sound
Model UPM-1P

CAUTIONS:

F3.15A  250V

ATTENTION: 

UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE F3.15A - 250V

User Panel with RMS option and Polarity and Attenuaing Audio Input Module

Содержание UMS-1P

Страница 1: ...Keep these important operating instructions UMS 1P Self Powered Subwoofer Superior engineering for the art and science of sound OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS...

Страница 2: ...This device complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC This device also complies with EN 55103 1 2 Operation is subject to the following tw...

Страница 3: ...imum zu reduzieren den Lautsprecher vom Stromnetz trennen bevor ggf ein Audio Schnittstellensignalkabel angeschlossen wird Das Netzkabel erst nach Herstellung aller Signalverbindungen wieder einsteck...

Страница 4: ...nadvertent disconnection It also has a looping feature discussed below which allows multiple UMS 1Ps to be daisy chained The blue connector serves as the power input the gray con nector is used in loo...

Страница 5: ...on the UPM 1P i e the 3 15A fuse is used whether the product is set for 100V 115V or 230V If a fuse should ever trip contact your local Meyer Sound Service Center or the Service Department at the Mey...

Страница 6: ...1P is powered by one channel of a pro prietary Meyer Sound amplifier utilizing complementary power MOSFET output stages class AB bridged 225 Wrms ch burst The UMS 1P employs two sepa rate methods of l...

Страница 7: ...udspeaker The following graph represents the approximate change in dB SPL for fre quencies under 125Hz of a single UMS 1P as it is moved away from a boundary Some frequencies will be aided by this rea...

Страница 8: ...when conducting these tests Polarity within a UMS 1P If the driver or circuit wiring has been removed or disassembled it is essential to check the polarity between drivers and between adjacent loudspe...

Страница 9: ...the signal path 2 Make sure the XLR cable is securely fastened to the XLR audio input con nector 3 Send the audio signal to another loudspeaker to insure signal presence and that the level is within t...

Страница 10: ...ignal Common Mode 425kHz low pass Differential Mode 142kHz low pass 50dB 50Hz typically 60dB 65db 1kHz typically 75dB 80kHz Complementary MOSFET output stages class AB bridged 225 Wrms channel 02 Powe...

Страница 11: ...etwork S e r v i c e W i n k R e s e t A c t i v i t y Remote Monitor System 2 3 0 115 Polarity Loop Input On Temp Limit Attn dB 18 15 12 6 3 9 0 Earth Chassis Case 220k GND Circuit 1 2 3 1 2 3 10k Ba...

Страница 12: ...2 Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 tel 510 486 1166 fax 510 486 8356 e mail techsupport meyersound com http www meyersound com CONTACT INFORMATION 05 86 002 01 Rev...

Отзывы: