A

MPLIFIER

N

ATURAL

C

ONVECTION

C

OOLING

S

YSTEM

The USM-P employs a natural convection
cooling system that depends on air flow
from below the cabinet over the
heatsink. 

Allow for proper ventillation

of fresh air when using the speaker.

If the temperature of the heatsink
reaches 85°C (185°F), the 

On/Temp.

LED on the rear panel turns from green
(On) to red (Temp.) and the limiter
threshold is lowered to a safe level to
prevent the amplifiers from overheating.
Under  high temperature conditions the
limiter threshold is reduced to 6 dB.
When the heatsink tmeperature decreas-

es to 75°C (167°F), the 

On/Temp.

LED

changes from red to green and the lim-
iter threshold returns to normal.

The heatsink gets too hot to
touch during normal opera-
tion. Use extreme caution
near the rear of the cabinet.

F

AN

A

SSEMBLY

K

IT

While convection cooling is adequate
for most applications, driving the USM-
P into frequent limiting under severe
temperature conditions, or where venti-
lation is restricted, an optional fan kit
is available to maintain a safe operat-
ing temperature. The easy-to-install

fan, powered by the 

24V Fan

user panel

connector, blows air directly onto the
heatsink. The fan speed increases as the
heatsink temperature rises, which main-
tains a safe operating temperature with
minimal fan noise. Contact Meyer Sound
to order the fan kit.

P

OWER

S

UPPLY

F

AN

The power supply is cooled by a single small
internal fan that turns on low when the unit
is first powered up. The fan doubles its speed
as the system is driven with audio. Since the
fan draws air in from, and exhausts it out the
side of the cabinet, there must be at least six
inches on the amplifier's side of the cabinet
and adequate air flow. 

7

USM-1P (Side View)

!

COVERAGE

The Constant Q design of the horn allows
frequencies outside of the coverage area
of the speaker to attenuate quickly.  This
is excellent for monitoring where several
different monitors are used in close
proximity. When placing the monitor
carefully consider the coverage pattern
of the USM-P and USM-100P.

The USM-1P's coverage area is: 

-6 dB points:

45° H x 45° V 

-10 dB points:

65° H x 65° V

The USM-100P's coverage area is:

-6 dB points:

100° H x 40° V 

-10 dB points:

120° H x 60° V

USM-1P (Top View)

USM-1P (Front View)

USM-100P (Side View)

USM-100P (Top View)

USM-1P (Top View)

The following drawings illustrate the coverage area of each horn from three different
perspectives in order to depict the three dimensional coverage pattern.

Содержание Self-Powered Loudspeaker Systems USM-P Series

Страница 1: ...p these important operating instructions USM P Series Self Powered Loudspeaker Systems OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS USM 1P USM 100P Superior engineering for the art and science of sou...

Страница 2: ...0 010m peak to peak excursion Office of Quality Manager Berkeley California USA May 18 2000 Operating Temperature Nonoperating Temperature Humidity Operating Altitude Nonoperating Altitude Shock Vibr...

Страница 3: ...imum zu reduzieren den Lautsprecher vom Stromnetz trennen bevor ggf ein Audio Schnittstellensignalkabel angeschlossen wird Das Netzkabel erst nach Herstellung aller Signalverbindungen wieder einsteck...

Страница 4: ...nd adheres to this definition NOTE Unfortunately beamwidth is often used to describe the angle at which the sound pressure decreases 10dB from its on axis amplitude because many listeners perceive thi...

Страница 5: ...10 seconds It is used to calculate the temperature increase in cables which is used to select cables that conform to electrical code standards It is also used to select the rating for slow reacting t...

Страница 6: ...uator knob operates between 0 dB no level attenu ation in a fully clockwise position to 12 dB in a fully counter clockwise posi tion REMOTE MONITORING SYSTEM The USM P can be equipped to operate with...

Страница 7: ...r blows air directly onto the heatsink The fan speed increases as the heatsink temperature rises which main tains a safe operating temperature with minimal fan noise Contact Meyer Sound to order the f...

Страница 8: ...ied electronics technicians with access to a test bench can request the following documents from Meyer Sound Troubleshooting Guide The Low Frequency Driver Replacement Procedure and The High Frequency...

Страница 9: ...SOME SOUND BUT THE ON TEMP LED TURNS FROM GREEN TO RED This occurs when the heatsink tempera ture reaches 85 C 185 F indicating that the amplifier is thermally over loaded The limiter threshold has dr...

Страница 10: ...loor to max SPL 6 db at 100 H x 40 V 10 dB at 120 H x 60 V 6 db at 45 H x 45 V 10 dB at 60 H x 60 V 900 Hz 1000 Hz 15 inch cone driver 3 inch diaphragm compression driver Differential balanced input c...

Страница 11: ...nel and optional module are described on page 6 of this document USER PANELAND OPTIONAL MODULES User Panel with RMS option and Polarity and Attenuaing Audio Input Module Looping Polarity and Attenuain...

Страница 12: ...832 San Pablo Avenue Berkeley CA 94702 tel 510 486 1166 fax 510 486 8356 e mail techsupport meyersound com http www meyersound com CONTACT INFORMATION 12 All units in inches PHYSICAL DIMENSIONS 05 089...

Отзывы: