WEATHER PROTECTION COMPONENTS

Standard Weather Protection

Meyer Sound designs toward an IP rating of IPX4 (see “IP 
Ratings” on page 35) for Standard Weather Protection, 
which includes the following components:

• Wood treatment—Prior to cabinet manufacturing, the 

raw wood receives a special treatment that penetrates 
and stabilizes the wood fibers to withstand a wide range 
of temperatures and exposure to extreme humidity.

• Cabinet finishing—The assembled cabinets receive a 

highly impervious finish that includes a sealing primer 
and a finishing topcoat. The coatings are applied on both 
surfaces, with one coat on the interior and two on the 
exterior. The final step is a two-part modified acrylic 
urethane similar to that used in military applications.

• Driver treatment—All cone drivers are coated with a 

water-resistant sealant.

• Exterior protection—Grille frames are coated to resist 

corrosion, and all components that mount to the cabinet 
use custom gaskets and stainless steel fasteners.

• Removable rain hood—The rain hood is designed to 

shield connectors even in wind-driven rain.

INSTALLATION PRACTICES

Meyer Sound assumes normal and accepted installation 
practices are used when installing Meyer Sound 
Loudspeakers outdoors. Deviation from such practices may 
cause weather protection to be ineffective and void the 
warranty for the loudspeaker.

Examples of unacceptable and acceptable installation 
practices include:

• Loudspeakers installed outdoors should not face 

upward.

• Loudspeakers with a rain hood should be installed in 

such a way that the rain hood opening is not facing any 
direction but down.

• Meyer Sound-supplied rigging components should not 

be modified (for example, by drilling additional holes in a 
MUB for mounting to a wall). When an installer/integrator 
modifies a Meyer Sound supplied rigging component to 
support their installation method, it is considered 
compromised and out of warranty.

• All loudspeaker cabling must be installed with a 

“drip

-

loop” or equivalent method to ensure that rain or 

water is NOT wicked toward the loudspeaker.

If in doubt about an installation method, contact Meyer 
Sound Technical Support for assistance.

Always discuss the environmental conditions of your Meyer 
Sound installation with your Sales Manager, and verify the 
availability of Weather Protection for your selected 
loudspeaker models. The Sales Manager, together with 
Technical Support, will verify the appropriate level of 
weather protection for the loudspeakers and related rigging 
hardware.

Содержание LYON-M

Страница 1: ...Keep these important operating instructions Check www meyersound com for updates OPERATING INSTRUCTIONS LINE ARRAY LYON Linear Line Array Loudspeaker...

Страница 2: ...be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written permission from Meyer Sound CAL Compass Go by M...

Страница 3: ...the replaceable fuse is the only user serviceable item When replacing the fuse only use the same type and the same value 15 Refer all other servicing to qualified service personnel Servicing is requi...

Страница 4: ...ter Sonneneinstrahlung fern und stellen Sie es nicht in der N he von w rmeabstrahlenden Ger ten z B Heizger t oder Herd auf Bei Ausstattung mit einem externen Sicherungshalter ist die austauschbare Si...

Страница 5: ...onerlo a la luz solar directa No instale la unidad cerca de aparatos que emitan calor como un calefactor o una estufa Si est equipado con un portafusibles externo el fusible reemplazable es el nico el...

Страница 6: ...LYON OPERATING INSTRUCTIONS vi...

Страница 7: ...r 3 Amplification and Audio 15 Audio Connectors 15 Cable Rings 16 TruPower Limiting 16 Amplifier Cooling System 17 Chapter 4 QuickFly Rigging 19 Important Safety Considerations 19 LYON Rigging Options...

Страница 8: ...eather Protection 33 Weather Protection Components 34 Installation Practices 34 IP Ratings 35 Appendix C Rain Hoods 37 LYON Collapsible Rain Hood 37 LYON Quick Clip Rain Hood 38 Appendix D Specificati...

Страница 9: ...edge technology housed in a lighter and more compact cabinet Optimized rigging and self powered configuration streamline both setup and breakdown for LYON systems LYON is ideal for medium to large sca...

Страница 10: ...Windows based computer Convenient XLR 5 pin connectors allow the use of composite cables carrying both RMS and balanced audio signals XLR 3 pin audio connectors are also available LYON offers intuiti...

Страница 11: ...phase Wye distribution system with the loudspeaker load distributed across all three phases with each loudspeaker connected to a single line and common neutral and earth ground lines This system deliv...

Страница 12: ...L Line N Neutral PE Protective Earth or Ground How AC power cables are wired is determined by the type of AC power distribution system used see AC Power Distribution on page 11 When wiring AC power ca...

Страница 13: ...econd The burst current is used as a rating for magnetic breakers It is also used for calcu lating the peak voltage drop in long AC cable runs according to the following formula V pk drop I pk x R cab...

Страница 14: ...range If the problem persists contact Meyer Sound Technical Support ELECTRICAL SAFETY GUIDELINES Make sure to observe the following important electrical and safety guidelines The powerCON 32 connecto...

Страница 15: ...m AUDIO CONNECTORS LYON is available with XLR 3 pin or 5 pin connectors for audio Input and audio Loop output Figure 10 and Figure 11 XLR 5 pin connectors accommodate both balanced audio and RMS signa...

Страница 16: ...ms into 600 ohms to yield the maximum SPL over the operating bandwidth of the loudspeakers To calculate the load impedance for the looped loudspeakers divide 10 kOhms the input impedance for a single...

Страница 17: ...1 second If the LEDs remain lit for longer than 3 seconds the loudspeaker enters hard limiting where Increases to the input level have no effect Distortion increases due to clipping Drivers are subjec...

Страница 18: ...LYON OPERATING INSTRUCTIONS 18...

Страница 19: ...s 7 16 x 1 50 inch red button PN 134 051 qty 4 included 3 4 inch or 7 8 inch MVP motor Vee plate PN 40 215 184 01 20 lb 9 1 kg Fine tunes the horizontal aim of arrays compatible with MTG LEO M MTG LYO...

Страница 20: ...to expand the array s splay angles during installation so the blue locking pins can be more easily inserted PBF LYON Pull Back Frame Attached to bottom cabinet to provide pull back for extreme array...

Страница 21: ...to adjust the horizontal aim of the array MTG LYON Top Grid Oriented for maximum array downtilt with three pick up points and four motors 12 LYON M Primary array coverage 4 LEOPARD Downfill coverage...

Страница 22: ...d by the front GuideALink positions Rear GuideALinks can be pinned in either of two positions extended or stowed Front GuideALinks determine the loudspeaker splay angles and are configured with the ye...

Страница 23: ...ick release pins in the blue LOCKING positions must be moved to the STOW PIN position before either lifting or lowering an array The removal of the quick release pins from theLOCKING positionsallows t...

Страница 24: ...LYON OPERATING INSTRUCTIONS 24...

Страница 25: ...e Wink option in RMS which lights the Wink LED on the RMS module of that particular loudspeaker Conversely a loudspeaker can be identified in Compass RMS by pressing the Identify button on the loudspe...

Страница 26: ...ws you to dis able Mute and Solo functions to eliminate any possibility of accidentally muting loudspeakers RMS Network Connectors The Weidmuller 2 conductor locking connectors transfer data to and fr...

Страница 27: ...loudspeaker systems and definition of the environment in which they operate including air temperature pressure humidity and even the location and composition of surfaces Importation of CAD DXF files...

Страница 28: ...nt summation Processing tools for inputs and outputs include delay parametric EQ and U Shaping EQ Output processing also includes polarity reversal Low Mid Beam control LMBC atmospheric correction and...

Страница 29: ...as some or all of the output processing filters and settings may be over written DELAY INTEGRATION Delay Integration aligns the phase responses of different loudspeaker model families Select the prod...

Страница 30: ...LEO magenta line LYON blue line have been set to target phase curves with a frequency of 100 Hz pc100 The phase responses are now much more closely aligned than without Delay Integration Figure 22 LEO...

Страница 31: ...rward facing with rear facing between them The Front Facing selection for most models does not alter the signal processing The Rear Facing selection usually inverts the polarity relative to the Front...

Страница 32: ...LYON OPERATING INSTRUCTIONS 32...

Страница 33: ...speaker in a similar installation that is shaded by trees and exposed only to rainfall The constant exposure to direct UV radiation and a salt air environment will cause a loudspeaker to wear more qui...

Страница 34: ...nd accepted installation practices are used when installing Meyer Sound Loudspeakers outdoors Deviation from such practices may cause weather protection to be ineffective and void the warranty for the...

Страница 35: ...on against solid objects Definition Second Digit Protection against liquids Definition X Characteristic numeral is not required to be specified X Characteristic numeral is not required to be specified...

Страница 36: ...LYON OPERATING INSTRUCTIONS 36...

Страница 37: ...removable rain hood for indoor outdoor touring and permanent outdoor installations Both rain hoods protect the loudspeaker s connectors from water intrusion LYON COLLAPSIBLE RAIN HOOD The LYON collap...

Страница 38: ...s Figure 25 LYON QUICK CLIP RAIN HOOD The LYON quick clip removable rain hood Figure 26 is easily attached and removed with its two winghead studs The quick clip rain hood is ideal for indoor outdoor...

Страница 39: ...APPENDIX C RAIN HOODS 39 3 Make sure to tighten the winghead studs one quarter turn so they fully lock Figure 26 LYON with Quick Clip Rain Hood...

Страница 40: ...LYON OPERATING INSTRUCTIONS 40...

Страница 41: ...ry loading Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12 5 dB B noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the mo...

Страница 42: ...AC Note AC power cabling must be of sufficient gauge so that under burst rms current con ditions cable transmission losses do not cause the loudspeaker s voltage to drop below the specified operating...

Страница 43: ...he dimensions and weight for the MTG LYON top grid and MCF LYON caster frame refer to the MTG LYON Assembly Guide PN 05 232 097 01 available at www meyersound com LYON M Dimensions 35 15 893 mm 21 00...

Страница 44: ...For the dimensions and weight for the MTG LYON top grid and MCF LYON caster frame refer to the MTG LYON Assembly Guide PN 05 232 097 01 available at www meyersound com LYON W Dimensions 35 15 893 mm 2...

Страница 45: ...y to cause harmful interference in which case the user will be required to correct the interference at their own expense This device complies with Part 15 of the FCC rules Operation is subject to the...

Страница 46: ...er Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 1 510 486 1166 meyersound com 2014 2020 Meyer Sound Laboratories Inc All rights reserved LYON Operating Instructions PN 05 232 005 01...

Отзывы: