![Meyer Sound 750-LFC Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/meyer-sound/750-lfc/750-lfc_operating-instructions-manual_1781791044.webp)
750-LFC OPERATING INSTRUCTIONS
44
AMPLIFIER
Type
Two-channel, open-loop, class D
Total Output Power
3100 W peak
Note:
Peak power based on the maximum unclipped voltage the amplifier will produce
into the nominal load impedance.
THD, IM, TIM
<0.02%
Cooling
Convection
AC POWER
Connectors
powerCON 20 input with loop output
Automatic Voltage Selection
90–265 V AC; 50–60 Hz
Safety Rated Voltage Range
100–240 V AC, 50–60 Hz
Turn-on/off Points
Turn-on: 90 V AC; Turn-off: none; internal fuse protection above 265 V AC
Current Draw
115 V AC
230 V AC
100 V AC
Idle
0.39 A rms
0.38 A rms
0.42 A rms
Maximum Long-Term Continuous 5.3 A rms
2.7 A rms
6.2 A rms
Burst
9.2 A rms
4.4 A rms
10.7 A rms
Maximum Instantaneous Peak
15.3 A peak
7.8 A peak
18 A peak
Inrush
<20.0 A peak
RMS NETWORK (OPTIONAL)
Two-conductor, twisted-pair network, capable of reporting all operating parameters of
amplifiers to system operator’s host computer.
PHYSICAL
Dimensions
21.80 in (554 mm) W
20.30 in (515 mm) H
20.88 in (530 mm) D
Dimensions (with rigging)
21.55 in (547 mm) W
20.43 in (519 mm) H
20.88 in (530 mm) D
Weight
89 lb (40.3 kg)
Weight (with rigging)
105 lb (47.6 kg)
Enclosure
Premium multi-ply birch with slightly textured black finish
Protective Grille
Powder-coated, hex-stamped steel with acoustical black mesh
Rigging
Optional MRK-750 rigging kit with end frames and captive GuideALinks secured with
0.25 in x 0.53 in quick release pins that allow (0°, 1.5°, 3.25°, and 4.75° splay angles);
detachable side handles. Rigging allows ground-stacked, flown, and cardioid
configurations
Pole Mount
U.S. version: 1 1/2 in (38 mm)
E.U. version: 1 3/8 in (35 mm and M20 thread at the bottom)
ENVIRONMENTAL
Operating Temperature
0° C to +45° C
Non Operating Temperature
–40° C to +75° C
Humidity
To 95% at 45° C (non-condensing)
Operating Altitude
To 5,000 m (16,404 ft)
Non Operating Altitude
To 12,000 m (39,000 ft)
Shock
30 g 11 msec half-sine on each of 6 sides
Vibration
10 Hz – 55 Hz (0.010 m peak-to-peak excursion)
Содержание 750-LFC
Страница 6: ...750 LFC OPERATING INSTRUCTIONS vi...
Страница 18: ...750 LFC OPERATING INSTRUCTIONS 18...
Страница 22: ...750 LFC OPERATING INSTRUCTIONS 22...
Страница 36: ...750 LFC OPERATING INSTRUCTIONS 36...
Страница 42: ...750 LFC OPERATING INSTRUCTIONS 42...
Страница 48: ...750 LFC OPERATING INSTRUCTIONS 48...
Страница 49: ......
Страница 50: ......
Страница 51: ......