9.5
Inspection, checking and adjusting work
9.5.1
Air maintenance unit
Note:
The air maintenance unit has an automatic condensation outlet.
Note:
The air maintenance unit filter must be replaced annually.
Fig. 9-3
Air maintenance unit
Legend
1
Pressure regulator
2
Pressure gauge
3
Filter housing
4
Pressure switch
Procedure
1
Remove the filter housing
/3.
2
Replace the filter.
3
/3.
4
Connect the compressed air.
5
Check the air pressure with the pressure gauge
/2 (6 bar).
6
Set the pressure with the pressure regulator
Note:
Pressure switch setting Fig. 9-3/4: 5 bar (falling)
Any response by the pressure switch is displayed on the screen by a message.
CAUTION
Escaping air can cause eye and skin injuries!
Make sure that the there is no pressure in it when working
on the compressed air system.
Work carefully!
!
1
2
3
4