Mex K633X90 Скачать руководство пользователя страница 24

RECIRCULATION MODE AIR OUTLET 

Insert  the  connection  extension  pieces
laterally in air outlet connection.

Make sure that the outlet of the extension
pieces  is  horizontally  and  vertically
aligned with the chimney outlets.

Connect  the  air  outlet  connection  to  the
hood body outlet using either a flexible or
rigid pipe with 

 150mm.

Ensure that the activated charcoal filters
have been inserted.

ELECTRICAL CONNECTION 

The electrical tension must correspond to the tension noted on the label
placed inside the cooker hood.

Connect the electrical plug, where provided, to the an easily accessible
outlet in conformity with local standards in force.

Where  an  electrical  plug  is  not  provided  (

for  direct  connection  to

electrical  network

)  place  a  standards  approved  bipolar  switch  with  an

aperture distance of not less than 3mm (

accessible

) from the contacts.

Attention:

substituting the supply cable must be carried out by  an 

authorised professional. 

Air outlet 

connection

- 11 /Eng -

Connection

DUCTED MODE AIR EXHAUST SYSTEM 

When installing the ducted mode, connect the hood
to  the  chimney  using  either  a  flexible  or  rigid  pipe
with

 150mm.

Fix the pipe in position using sufficient pipe clamps
(not supplied).

Remove any activated charcoal filters.

Содержание K633X90

Страница 1: ...K633X90 K633X90...

Страница 2: ...2 vs 3 4 5 7 8 9 9 10 11 12 13 13 14 14...

Страница 3: ...3...

Страница 4: ...4 L H1 H2 H3 K633X90 898 465 470 55 K633X90 220 240 50 330 LED 2 x 1 K633X90...

Страница 5: ...5 800 E N L 800 mm min...

Страница 6: ...6 MEX S40 MEX S40 Steel Clean...

Страница 7: ...K633X90 A B C D E F A F E D C B...

Страница 8: ......

Страница 9: ...3 8...

Страница 10: ...10 D 8 2 ST5 X 15 4 M3 x 12...

Страница 11: ...11...

Страница 12: ...12 M3 X 12 4 ST4 X 8 2...

Страница 13: ...13 3 2 6 1 1 1 3 2 7 2 2 3 3...

Страница 14: ...14...

Страница 15: ...pecifications 4 SAFETY Read this first 5 7 8 10 11 Description of Parts Ducted vs Recirculation version Installation Mounting the hood body Connection Chimney assembly 12 Operation 13 Cleaning Mainten...

Страница 16: ...appliances often contain materials which if handled or disposed incorrectly could be potentially hazardous to human health and environment Please do not dispose of your old appliance with your househ...

Страница 17: ...Specifications Input Absorption 0W External Dimensions Dimension Model L H1 H2 H3 mm K633X90 AC220 240V 50Hz Motor LED Light 2 x 1W 4 Eng...

Страница 18: ...in which this appliance is installed has good permanent ventilation The distance between the bench top to the lower part of the hood must not be at least 80 cm or higher The exhaust from the canopy ra...

Страница 19: ...e slack in the cable so the appliance can be moved if servicing is ever necessary Lack warning 1 This appliance is not intended for use by persons Including children with reduced physical sensory or m...

Страница 20: ...Description of Parts A Chimney Mounting Bracket B Upper Chimney Cover C Lower Chimney Cover D Motor Housing Section F Aluminum Filters 7 Eng F E D C B A...

Страница 21: ...ondensation are then expelled to the outside In this mode only the aluminum filters are installed Recirculation mode In the recirculation mode air is drawn into the hood fats are trapped by the alumin...

Страница 22: ...ion height level Make a reference point at C Repeat this step on the other side Drill 8mm holes at center of marking points Insert wall plug in the wall Fix the hood body to wall using 2 ST5 x 35 scre...

Страница 23: ...h mounting bracket using 4 M3 x 12 screws Slide the lower c himney cover downwards and ensure t hat it is well seated on the hood body 10 Eng Mounting the hood body Before attaching the hood body tigh...

Страница 24: ...ood Connect the electrical plug where provided to the an easily accessible outlet in conformity with local standards in force Where an electrical plug is not provided for direct connection to electric...

Страница 25: ...ring that they are well seated Secure the sides of the brackets using 4 screws M3 X 12 supplied Lower chimney Slightly widen the two sides of the chimney and hook them between the upper chimney and th...

Страница 26: ...on Switches the extractor motor on and off at high speed Used for eliminating the highest cooking vapors emission including long periods Blower Off with Delay Timer Button Switches the extractor motor...

Страница 27: ...ace the new charcoal filters Contact technician no airflow jammed High temperature Motor cuts after a safety device activated The kitchen is not sufficiently ventilated few minutes The hood is install...

Страница 28: ...K633X90...