Transcutaneous Electrical Nerve Stimulator   

TENS 212 

Instruction Manual 

  Read before using

 

 

Содержание TENS 212

Страница 1: ...Transcutaneous Electrical Nerve Stimulator TENS 212 Instruction Manual Read before using ...

Страница 2: ...ONS 2 DANGER 3 ABOUT THE DEVICE 3 THE DEVICE CONTROLS 4 ATTACHING THE LEAD WIRES 5 ELECTRODE SELECTION AND CARE 5 TIPS FOR SKIN CARE 5 CONNECTING THE DEVICE 6 BATTERY INFORMATION 6 CHANGING THE BATTERY 7 THE TENS 212 7 TROUBLESHOOTING 7 TECHNICAL SPECIFICATIONS 8 Procedure for Setting the Compliance Meter Special For Clinician 9 ...

Страница 3: ...ring the applicable warranty period Mettler Electronics Corp will at its discretion either repair or replace the Product without charge Cables electrodes the case and battery are not covered under this warranty For service under this warranty the Product must be returned by the buyer within the applicable warranty period to Mettler Electronics Corp Shipping charges to and from Mettler Electronics ...

Страница 4: ... law of the state in which he she practices Observe your practitioner s precise instructions and let him her show you where to apply the electrodes For a successful therapy the correct application of electrodes is an important factor Carefully write down the settings your medical practitioner recommended Indications for use This device is a prescription device and only for symptomatic relief of ch...

Страница 5: ...se of the irritation can be determined z Effectiveness is highly dependent upon patient selection by a person qualified in the management of pain patients z If the device treatment becomes ineffective or unpleasant stimulation should be discontinued until reevaluation by a medical practitioner z Always turn the device off before applying or removing electrodes z Skin irritation and electrode burns...

Страница 6: ...odes are Burst B Continuous C and Modulation M TIME Treatment Time of device can be pre selected or set with the Time key There are three programs with fixed durations of 15 30 and 60 minutes and one program of continuous output Press the key until engaged in position desired 15 min 15 min symbol on 30 min 15 30 min symbols on 60 min 15 30 and 60 min symbols on Continuous 15 and 30 min symbols on ...

Страница 7: ...age of your electrodes To avoid high current density be sure to use electrodes that are no smaller than those provided with the TENS 212 TIPS FOR SKIN CARE Good skin care is important for comfortable use of your device z Always clean the electrode site with mild soap and water rinse well and blot dry thoroughly prior to applying the electrode z Any excess hair should be clipped not shaved to ensur...

Страница 8: ...ect Treatment Settings Check and be sure your unit is set to the proper settings as recommended by your medical practitioner 6 Adjusting Channel Intensity Control Locate the intensity control knobs at the top of the unit Slowly turn the intensity control knob for Channel 1 clockwise until you reach the intensity recommended by your medical professional Always start with the lowest step and increas...

Страница 9: ...store in a cool dry location TROUBLESHOOTING If the device does not function properly 1 Make sure the battery is properly installed or replace the battery Be sure to observe proper polarity markings when replacing the battery If the low battery indicator appears when the unit is turned on replace the battery and check again 2 If the intensity has been adjusted and there is no stimulation check tha...

Страница 10: ...ts 2 Bursts sec 9pulses Burst 100 Hz width is adjustable C Continuous mode Pulse rate pulse width and intensity are adjustable M Modulated Width Pulse width is automatically varied in an interval of 6 seconds The modulation range of pulse width is from setting value to 35 less than the control setting value then returns to the setting value Rate width and intensity are fully adjustable Wave form A...

Страница 11: ... After you enter the Compliance mode the patient compliance meter appears on the LCD with the hr symbol 3 To reset the compliance meter value When you want to reset the compliance meter value for a new treatment cycle follow the steps listed below When you are in the Compliance mode first press and release the MODE key Then press and release the Rate key This will reset the treatment time hours to...