2
S
CALE
P
ROGRAM
M
ODE
The following steps are
only
required for the scale configuration bar
codes located on pages 5 - 19 (
bar codes beginning with 996.
)
1.
Power down
the scanner/scale.
Then, temporarily remove the
scale platter and place it in a safe
location.
Figure 1.
2.
Cut and remove
the security seal over the program/calibration switch cover.
See
Figure 2
below for seal location on the StratosE and the StratosH
models. See
Figure 3
on page 3 for the seal location on the StratosS.
Once the security seal is cut the unit
cannot
be place in service until
it is calibrated, sealed and certified by local Weights and Measures
authority.
3.
Remove
the M3 screw securing the switch cover in place. Store the cover
and screw in a safe location. They will be needed again after the scale is
configured and calibrated.
Always follow all Electro-Static Discharge (ESD) procedures when
exposing the internal scanner/scale components.
4.
Enter the scale program mode
by sliding the switch to the
program
position. See
Figure 2
below for the switch location on the StratosE and
StratosH. See
Figure 3
on page 3 for the switch location on the StratosS.
Figure 2. StratosE and StratosH Calibration Seal and Switch Location