background image

 

10

Installation 

Basic Operation  

In order for the Optimus to operate properly, an application program must be loaded onto the

 

PDT

.  

It is 

possible for the Optimus to power up without at active application.  On power up if the Optimus has no 
application program loaded, then the following Program Manager menu options will appear on the 
display:  
 

M

ENU 

O

PTIONS

D

ESCRIPTION

 

Download 

This option allows the user to download application programs (*.SHX), BASIC run-time 
(bas.ops.shx), BASIC programs (*.SYN) or font files to the terminal. There are 6 resident 
locations and one Active Memory.  A maximum of 7 programs can be downloaded to the 
terminal.  The application program downloaded to the Active Memory will be the only activate 
program running. In order to activate one of the other programs.  Immediately after 
downloading, input a name for the program desired or just press the enter key to keep its 
current name if one is applicable.  This will enable the user to download the program.  The 
application file’s type, name, and size will be shown on the list of programs when entering the 
Download or Activate menu of the Program Manager. The file type is a small letter that 
follows the program number (01~06), it can be either ‘b’, ‘c’ or ‘f’ which represents BASIC 
program, C program or font file respectively. The program name is up to 12 characters and 
the program size is in units of K bytes. 
NOTE: In order to delete a program, select the program designated for deletion.  From the 
program information screen, press the Alpha/Function key, then zero.   

Activate 

This option will enable the use to activate one of the resident programs.  In order to 
accomplish this, the user must copy one of the 6 resident programs to the Active Memory.  
Upon activation of the new program the original program in the Active Memory will be 
replaced. 

Note:

 A font file cannot be activated, and a BASIC program cannot be activated if 

the BASIC run-time does not exist. 

Upload 

The 

Upload

 option gives the user additional method for retrieving an application program.  It 

allows a user to transmit the application programs to a host PC or another terminal. This 
function also allows a terminal to be cloned without going through a PC. 

 
Selecting and successfully completing one of these three menu options will enable the OptimusR to 
begin functional operation.

 

 

 

Communication and Data Collection Setup 

The OptimusR Series has various ways of communicating with a host device.  Depending on the model 
of Optimus, it can communicate via RS232, USB, or via a WiFi connection.  The OptimusR can store 
data in the unit or send data real time via a WiFi connection.  The OptimusR has the ability to utilize a 
RS232 or USB connection to communicate to a host device for both application program downloads 
and data uploads.  The OptimusR includes either a USB or RS232 cable.  In order to begin an 
application download or data transfer the following steps would need to be followed. 
 

1.  Remove the Optimus cradle, the power supply, and either the USB or RS232 cable from the box. 
2.  Plug the power supply into a power outlet and insert the other end into the cradle.  The red LED 

on the cradle will illuminate if the power supply is connected correctly. 

Содержание SP5600 OptimusR

Страница 1: ...METROLOGIC INSTRUMENTS INC SP5600 OptimusR User s Guide...

Страница 2: ......

Страница 3: ...reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Prod...

Страница 4: ...Screen 8 The Lithium Battery 8 Installation Getting Started 9 Basic Operation 10 Communication and Data Setup 10 Data Upload 12 System Menu 13 System Menu Options 13 Application 17 Programming the Te...

Страница 5: ...3...

Страница 6: ...such as inventory control shop floor management warehousing operations and distribution operations Key Product Features Up to 8 MB RAM capable of storing over 400 000 records Easy to use Optimizer pr...

Страница 7: ...TION 1 Multi functional Keypad 2 Scan Button 3 LCD display 4 Red Output Window Laser Aperture 5 Speaker for audible indicators 6 Protective rubber bumpers 7 Battery Compartment 8 Communication Ports R...

Страница 8: ...teristics 4 3 2 5 6 1 Figure 2 Cradle Features ITEM NO DESCRIPTION 1 LED Transmission Indicator 2 LED Power indicator 3 Battery Contacts 4 IR communication port 5 Rubber Footpads 6 RS232 Communication...

Страница 9: ...urther description of key operation 3 ARROW Arrow The two arrow keys located below the Scan key are used to toggle up and down between menu selections 4 ESC Escape This key is used to stop and exit cu...

Страница 10: ...100 pixels y Resolution y Maximum of 8 lines x 16 characters y Minimum of 4 lines x 12 characters y Displays alpha characters numbers and symbols y Automated back light The Lithium Ion Battery The Opt...

Страница 11: ...an angle with the battery contacts inserted first 3 Push the Li ion battery the remainder of the way into the compartment The battery will fit snuggly into place 4 Close the battery compartment by sl...

Страница 12: ...s the Alpha Function key then zero Activate This option will enable the use to activate one of the resident programs In order to accomplish this the user must copy one of the 6 resident programs to th...

Страница 13: ...option 5 This will open additional menu options Select the Transfer Files option 6 Select Get Program on the next menu The unit is now ready to download an application program 7 Place unit in cradle...

Страница 14: ...elessly and as such has the capability of communicating that data in real time The unit needs to be setup to communicate with the network as follows 1 With the Optimus powered off press and hold the 7...

Страница 15: ...icate that the Optimus is powered on 3 The Optimus will display the system menu The system menu will list a number of options Information Settings Tests Memory Power Load Program 802 11 Menu System Me...

Страница 16: ...both operation and diagnostics Depending on the application program that is in the active memory will determine which tests can be performed and are available to the user The following table provides...

Страница 17: ...ns data as long as power is being supplied SRAM does not have to be periodically refreshed and provides quick access to data This is the location that the data collected will be stored Flash memory Fl...

Страница 18: ...me WLAN Setting These are the Wireless Local Area Network settings 1 Local Name 2 SS ID 3 System Scale 4 Power Saving 5 Preamble 6 Ad Hoc Security The security settings provide network authentication...

Страница 19: ...e Note If the Application Generator is used to create the application program it will be necessary to download it to the terminal Programming the terminal There are three software tools available for...

Страница 20: ...host communication parameters COM port baud rate data bits parity and stop bit match with the Terminal s Verify that the communication port on the host device is not in use by another device Turn off...

Страница 21: ...4 Limited Print Contrast 35 minimum reflectance difference No Characters Read Up to 80 data characters Maximum number will vary based on symbology and density Beeper Operation 7 tones or no beep CPU 1...

Страница 22: ...Operation Li ion Battery Backup 3 7V 7 0mA hours rechargeable lithium battery Operation Over 200 hours Over 16 hours WiFi Laser Class CDHR and IEC Class 2 in accordance with IEC 60825 1 1993 A1 1997...

Страница 23: ...Shanghai 200000 Tel 1 856 537 6400 Tel 33 0 1 48 63 78 78 Tel 86 21 58692780 Fax 1 856 537 6474 Fax 33 0 1 48 63 24 94 Fax 86 21 58692782 Email info us metrologic com Email info fr metrologic com Ema...

Страница 24: ...S o Paulo SP Brasil Email info es metrologic com Tel 91 80 51256718 Tel 55 11 5182 7273 Fax 91 80 51256719 Fax 55 11 5182 7198 Metrologic European Repair Ctr Email info in metrologic com Email info s...

Страница 25: ...h can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reposition or relocate the receiving antenna Increase...

Отзывы: