background image

21

SYMPTOM

The unit powers up properly, lasers come on, but the unit does not scan and does not
beep when a bar code is presented

POSSIBLE CAUSE(S) 

SOLUTION

Beeper disabled. No tone selected

Enable beeper. Select tone

Scanning a particular symbology that is

UPC/EAN, Code 39, interleaved 2 of 5,

not enabled

Code 93, Code 128 and Codabar are enabled
by default. Verify that the type of bar code
being read has been selected

The scanner has been programmed for a

Verify that the bar code that is being scanned

character length lock, or a minimum

falls into the criteria. (Typical of Non-

length and bar code being scanned does
not satisfy the programmed criteria

UPC/EAN codes.) (

The scanner defaults to

a minimum of 4 character bar code

)

SYMPTOM

The scanner scans a bar code but the scanner locks up (green LED comes on and stays
on) after the first scan

POSSIBLE CAUSE(S)

SOLUTION

The scanner is configured to support

If the scanner is setup to support ACK/NAK,

some form of host handshaking but is

RTS/CTS, XON/XOFF or D/E, verify that

not receiving the signal

the host cable and host are supporting the
handshaking properly

SYMPTOM

The scanner scans and transmit but the data is not correct at the host

POSSIBLE CAUSE(S)

SOLUTION

The scanner’s data format does not

Verify that the scanner’s data format

match the host system requirements

matches that required by the host. Make sure
that the scanner is connected to the proper
host port

Содержание Orbit MS7100

Страница 1: ...METROLOGIC INSTRUMENTS INC MS7100 Series Fixed Projection Laser Scanner Installation and User s Guide MLPN 2408 Printed in USA October 1998...

Страница 2: ...r Brooklin 05 08 Techlink CEP 04571 090 S o Paulo SP Brasil Singapore 417818 Outside Brazil Tel 65 842 7155 Tel 55 11 5505 6568 Fax 65 842 7166 Fax 55 11 5505 1681 ant888 cyberway com sg info sa metro...

Страница 3: ...n PC Keyboard Wedge Interface 7 Scanner Parts 8 Audible Indicators 9 Failure Modes 10 Visual Indicators 11 Labels 12 Depth of Field Specifications 13 Optimal Depth of Field 13 Close Depth of Field 13...

Страница 4: ...iv Appendix A Design Specifications 27 28 Appendix B Default Settings 29 32 Appendix C Pin Assignments 33 35 Appendix D Warranty and Disclaimer 36 37 Appendix E Notices 38 39 Index 40 41...

Страница 5: ...arge easy to find optimal scan area Orbit increases the first pass read rate for maximum productivity The scanning head can be tilted vertically a full 30 for added flexibility when scanning various s...

Страница 6: ...owerLink cable with built in power jack Standard MLPN 54xxx 2 1m 7 straight cord short strain relief or Optional MLPN 53xxx 2 7m 9 coiled cord long strain relief xxx specifies connection to the host K...

Страница 7: ...ce the green LED will remain on for the duration of the beep 2 The scanner is shipped from the factory programmed with default settings To configure the MS7100 scanner to meet the host system s specif...

Страница 8: ...into the PC 2 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet Connect AC power to the transformer 3 Listen for a single beep that indicates the scann...

Страница 9: ...ck the AC input requirements of the power supply to make sure the voltage matches the AC outlet the socket outlet shall be installed near the equipment and shall be easily accessible Connect AC power...

Страница 10: ...n off the host system 2 Make the necessary PowerLink cable connections to the scanner and the host 3 Turn on the host system NOTE a When the scanner first receives power the red LED will turn on Then...

Страница 11: ...end of the adapter cable to the PowerLink cable leaving the neces sary termination exposed for connecting to the keyboard and the keyboard port on the PC Refer to Appendix C page 35 for pin assignmen...

Страница 12: ...ed as diagnostic indicators and mode indicators Refer to pages 9 11 for details Orbit Face Tilts 30 vertically o for variable position ing of the scan pattern Output Window Laser light emits from this...

Страница 13: ...the green light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to failure modes page 10 Three Beeps during operation During operation...

Страница 14: ...failure Return the unit for repair at an authorized service center Continuous Razzberry Tone with both LEDs off If upon power up the scanner emits a continuous razz berry tone then the scanner has an...

Страница 15: ...en Flash When the scanner successfully reads a bar code the green LED will flash and the scanner will beep once If the green LED does not flash or the scanner does not beep once then the bar code has...

Страница 16: ...unit One label contains information such as the model number date of manufacture serial number and notes that the device is a Class IIa laser product The other label states the device is an LASERKLASS...

Страница 17: ...13 Depth of Field Specifications based on 100 UPC bar codes Optimal Depth of Field default Close Depth of Field...

Страница 18: ...14 Normal Depth of Field Far Depth of Field...

Страница 19: ...15 Depth of Field by Minimum Bar Code Element Width Optimal Depth of Field default...

Страница 20: ...16 Close Depth of Field...

Страница 21: ...17 Normal Depth of Field...

Страница 22: ...18 Far Depth of Field...

Страница 23: ...es and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wip...

Страница 24: ...being supplied Some host system s cannot supply to the scanner from host enough current to power Orbit Use the power supply included with the scanner 3 beeps on Non volatile RAM failure Contact a Met...

Страница 25: ...does not satisfy the programmed criteria UPC EAN codes The scanner defaults to a minimum of 4 character bar code SYMPTOM The scanner scans a bar code but the scanner locks up green LED comes on and st...

Страница 26: ...e aspect ratio of the bar code is out of Check print mode The type of printer could tolerance be the problem Change print settings ie change to econo mode or high speed The bar code may have been prin...

Страница 27: ...ntercharacter delay SYMPTOM The unit is transmitting each character POSSIBLE CAUSE S SOLUTION Configuration is not correct Increase the interscan code delay setting Adjust whether the F0 break is tran...

Страница 28: ...looking for RS 232 data Com port not operating properly Check to make sure that the baud rate and parity of the scanner and the communica tion port match and the program is looking for RS 232 data SYM...

Страница 29: ...tware and the scanner configuration match If the applica tion does not support RS 232 scanners a software wedge program that will take RS 232 data and place it into a keyboard buffer may be needed Thi...

Страница 30: ...be used for keyboard emulation only However many RS 232 programmable functions that are available in other Metrologic scanners are also available as keyboard wedge functions The most important selecta...

Страница 31: ...Keyboard Wedge RS 232 OCIA Light Pen IBM 46xx Stand Alone PC Keyboard Print Contrast 35 minimum reflectance difference No Characters Read up to 80 data characters Maximum number will vary based on sym...

Страница 32: ...Temperature 40EC to 60EC 40EF to 140EF Humidity 5 to 95 relative humidity non condensing Light Levels 4840 LUX 450 foot candles Shock Designed to withstand 1 m 3 1 drops Contaminants Sealed to resist...

Страница 33: ...232 Pen 46XX UPC EAN T T T T T T T T T T Code 128 T T T T T T T T T T Code 93 T T T T T T T T T T Codabar T T T T T T T T T T Interleaved 2 of 5 ITF T T T T T T T T T T MOD 10 Check on ITF T T T T T...

Страница 34: ...T T T Timeout 500 msecs Programmable in 50 msec steps MAX 6 35 seconds Same Symbol Rescan T T T T T T T T T T Timeout 1250 msecs Same Symbol Rescan T T T T T T T T T T Timeout 2000 msecs Intercharacte...

Страница 35: ...s Parity Space T T Baud Rate 9600 T T 8 Data Bits T T 7 Data Bits T T Transmit Sanyo ID Characters T T T T Nixdorf ID T T T T LRC Enabled T T T T UPC Prefix T T T T UPC Suffix T T T T Transmit AIM ID...

Страница 36: ...100msec steps MAX 800 msec Coupon Code 128 T T T T as code T T T T 39 Programmable Code Lengths 7 aval T T T T T T T T T T Programmable Prefix 10 avail T T Characters Suffix Characters T T Prefixes f...

Страница 37: ...mit Output 2 RS 232 Transmit Output 3 RS 232 Receive Input 3 RS 232 Receive Input 4 RDATA 4 RTS Output 5 RDATA Return 5 CTS Input 6 Clock in 6 DTR Input 7 Clock out 7 IBM 46XX Transmit 8 Clock in Retu...

Страница 38: ...the other end of the PowerLink Y type cable to the host and keyboard refer to page 7 for details Due to the variations in current supplied by the many available PC s Metrologic suggests the use of an...

Страница 39: ...ale connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the ne...

Страница 40: ...ch in the sole judge ment of Metrologic has been subjected to misuse neglect improper installation or accident nor does it extend to any Product which has been repaired or altered by anyone who is not...

Страница 41: ...nd haften nicht f r die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Ver ffentlichung oder des hierin beschriebenen Produkts Sie bernehmen ebenso keinerlei Eignungsgarantie o...

Страница 42: ...ard Remarque Apr s contr le de cet appareil on a not qu il r pondait aux valeurs limites de la classe A conform ment la partie 15 des directives de l administration f d rale am ricaine pour les t l co...

Страница 43: ...en Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung N B Dal controllo di questo apparecchio risulta che esso risponde ai valori limite per apparecchi digit...

Страница 44: ...7 Configuration procedures 5 7 Connector s 36 Current 4 7 21 29 34 35 Customer service 37 D DC transformer 28 Decode capability 27 Default Settings 29 32 Depth of field 13 18 Design specifications 27...

Страница 45: ...1 4 7 23 25 26 27 33 35 Pin assignments 33 35 Port 5 8 21 24 25 35 Powered by 5 6 PowerLink cable 2 4 8 33 35 Power supply 4 5 7 20 33 34 Programming guide 2 3 9 24 26 Protocols 26 Q Quick start 3 R...

Отзывы: