MDE-4354 Setting Up Metrologic® MS6720 Bar Code Scanner • August 2005 

Figure 1: Required Changes Inside the MCA

5

Insert the phone jack end of the scanner cable into the phone jack connector on the MCA 
(

Figure 1

).

6

Use the cable supplied with the scanner to connect the DB9 connector on the MCA (

Figure 1

to the SCANNER port on the POS distribution box.

7

Plug in the POS distribution box power supply.

8

Turn on the Profit Point POS terminal.
When you turn on the power to the Profit Point POS terminal, follow the instructions on the 
screen. The Profit Point terminal will then initialize and begin POS operations.

Performing Verification Sequence

While in Point-of-Sale operations, scan an item. The scanner should beep when the item is 
scanned.

• If the correct item description appears on the screen, the scanner is programmed correctly.
• If the message “# not on file” appears and the number shown on the screen matches the 

number under the scanned bar code, the scanner is functioning correctly, but the bar code 
cannot be identified. The display may not show the first or the last digit printed on the 
item. Press CLEAR MENU to cancel the item entry.

• If the screen does nothing or displays” Data Error on Scanner Port” or “Item Entry Error,” 

repeat the scan.  If the same message displays, the scanner may be programmed 
incorrectly.  Proceed with 

“Programming Sequence” on page 3

.

Note: The first time the scanner is turned on, the first scan may produce the error message 

“Data Error on Scanner Port” even if the scanner is programmed correctly.

Before

JP1 jumper/shunt on pins 2 and 3

JP2 jumper/shunt present

After

JP1 jumper/shunt on pins 1 and 2

JP2 jumper/shunt removed

power supply 
connector (not used)

phone jack 
connector

DB9 female 
connector

power supply 
connector (to be 
covered by power 
supply connector 
cover if supplied)

phone jack 
connector

DB9 female 
connector

Содержание MS6720

Страница 1: ...he cover Remove jumper shunt from JP2 and discard see Before in Figure 1 Move jumper shunt from JP1 pins 2 and 3 see Before in Figure 1 to JP1 pins 1 and 2 see After in Figure 1 If contained in shippi...

Страница 2: ...correctly If the message not on file appears and the number shown on the screen matches the number under the scanned bar code the scanner is functioning correctly but the bar code cannot be identified...

Страница 3: ...ng Guide is available at the following URL ftp ftp metrologic com pub download productmanuals 00 02186 pdf 3 Exit program mode by scanning in the bar code in Figure 10 4 The scanner should now be prop...

Страница 4: ...Programming Sequence Page 4 MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005...

Страница 5: ...5 Programming Sequence Bar Codes Figure 2 Load Defaults Note If necessary refer to MLPN 2186 page iv or un numbered last page Figure 3 Enable RS 232 Mode Note If necessary refer to MLPN 2186 page B 1...

Страница 6: ...Programming Sequence Page 6 MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005...

Страница 7: ...ence Figure 5 Set 9600 Baud Rate Note If necessary refer to MLPN 2186 page E 2 Figure 6 Set 1200 Baud Rate Note If necessary refer to MLPN 2186 page E 3 CAUTION Use only when IEE customer display will...

Страница 8: ...Programming Sequence Page 8 MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005...

Страница 9: ...Page 9 Programming Sequence Figure 7 Set 7 Data Bits Note If necessary refer to MLPN 2186 page E 4 Figure 8 Disable RTS CTS Handshaking Note If necessary refer to MLPN 2186 page E 14 Figure 9 Disable...

Страница 10: ...Programming Sequence Page 10 MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005...

Страница 11: ...4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005 Page 11 Programming Sequence Figure 10 Enter Exit Program Mode Note If necessary refer to MLPN 2186 page iii or un numbered next to last...

Страница 12: ...5000 http www gasboy com Printed in the U S A MDE 4354 Setting Up Metrologic MS6720 Bar Code Scanner August 2005 IEE is a registered trademark of Industrial Electronic Engineers Inc Metrologic and Sca...

Отзывы: