background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Copyright 

 
© 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this 
work may be reproduced, transmitted, or stored in any form or by any means 
without prior written consent, except by reviewer, who may quote brief 
passages in a review, or provided for in the Copyright Act of 1976. 
 

Trademarks 

 
Metrologic is a registered trademark of Metrologic Instruments, Inc.  
Products identified in this document are hereby acknowledged as 
trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their 
respective companies. 

 

Содержание Genesis MS7580

Страница 1: ...MS7580 Genesis Supplemental Guide for EAS Equipped Models ...

Страница 2: ...prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Trademarks Metrologic is a registered trademark of Metrologic Instruments Inc Products identified in this document are hereby acknowledged as trademarks registered or otherwise of Metrologic Instruments Inc or their respective companies ...

Страница 3: ...tenna Connection 2 EAS System Connection 3 Checkpoint EAS System Integration 3 Configuration Imager Configuration for EAS Applications 4 Operation EAS Tag Deactivation Range 6 Scanner and Cable Terminations Scanner Pinout Connections 8 Cable Connector Configurations 9 Antenna Disconnect 9 Limited Warranty 10 ...

Страница 4: ......

Страница 5: ...ecified cables listed below Any damage incurred from incorrect cable usage will void the limited warranty shown on page 10 EAS Cable Options Part Description The following cables are compatible with Checkpoint System devices MX 5S000 E 3 RS232 12V VLink Straight Black Cable with Built in Power Jack MX 5S235 E 3 USB 12V VLink Straight Black Cable with Built in Power Jack Non Locking Type A Connecto...

Страница 6: ...ottom of the imager s stand 2 Remove the socket screw securing the connector cover A 1 5 mm hex key is supplied 3 Remove the connector cover plate by lifting up the end and sliding the cover to the left 4 Insert the 2 pin box plug A into the receptacle on the imager s stand see Figure 2 5 Insert the cable s strain relief B into the channel on the stand see Figure 2 6 Re install the connector cover...

Страница 7: ...re Gauge Connection Type Solid Light Green Thin INTLK Terminal Solid Black Thin INTLK Terminal GND Interlock Red and White Thick Antenna Terminal Black and White Thick Antenna Terminal No Insulation Shield Antenna Shield Antenna Interlock functionality requires specific EAS device settings Consult the manufacturer s EAS system documentation for the appropriate switch and timing potentiometer setti...

Страница 8: ...below Disable EAS Support 3 3 7 2 0 0 2 Scan either the Enable Continuous Mode bar code or the Enable Regular Mode bar code Enable Regular Mode Regular Mode In regular EAS mode the imager will signal the EAS system to activate immediately after the area imager successfully transmits a bar code The area imager will signal the EAS system to deactivate after the configured EAS timeout expires 1 4 6 1...

Страница 9: ...will leave the EAS interlock signal asserted following a successful scan If the area imager commonly fails to deactivate EAS tags try increasing the value of the timeout setting Note The EAS timeout setting has no effect in continuous mode EAS Timeout 100 ms 8 4 6 0 0 0 EAS Timeout 500 ms 8 4 6 0 5 0 EAS Timeout 1s 8 4 6 0 1 0 0 EAS Timeout 5s 8 4 6 0 5 0 0 ...

Страница 10: ...e expected deactivation range Tag Storage Precaution Do not store tags within 45 7 cm 18 0 of the MS7580 Tags stored closer than 45 7 cm 18 0 may be unintentionally deactivated The precautionary area includes storage areas located under the MS7580 Proper tag deactivation requires the entire tag to pass through the expected tag deactivation range indicated in figures 4 and 5 Figure 4 Expected Tag D...

Страница 11: ...7 OPERATION Figure 5 Expected Tag Deactivation Area Top View Specifications are subject to change without notice ...

Страница 12: ...nect 4 No Connect 4 Tied to Pin 2 in Cable 5 Reserved 5 Reserved 6 RTS Output 6 USB D 7 No Connect 7 5VDC USB Power 8 RS232 Transmit Output 8 USB D 9 12V Power 9 12V Power 10 Shield Ground 10 Shield Ground SHELL Signal Power Ground SHELL Signal Power Ground 2 Pin Box Receptacle EAS Pin Function 1 EAS ANT 2 EAS ANT Figure 7 USB requires 12V power for pass through functionality Signals on Pin 6 and ...

Страница 13: ...00 E 3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 No Connect 5 Power Signal Ground 6 DSR 7 CTS Input 8 RTS Output 9 Host 12VDC Figure 8 9 Pin Female D Type USB MX 5S235 E 3 Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground Figure 9 USB Type A Non Locking Antenna Disconnect Figure 10 ...

Страница 14: ...duced from integration of the Product into any mechanical electrical or computer system The warranty is void if i the case of the Product is opened by anyone other than Metrologic s repair department or authorized repair centers or ii any software is installed on the Product other than a software program approved by Metrologic THIS LIMITED WARRANTY EXCEPT AS TO TITLE IS IN LIEU OF ALL OTHER WARRAN...

Страница 15: ......

Страница 16: ...00 05269A November 2008 Printed in China 2008 Metrologic Instruments Inc ...

Отзывы: