11
I
NSTALLING THE
S
CANNER TO THE
H
OST
S
YSTEM
Integrated USB:
Full Speed MS1690-40
Low Speed MS1690-38
1. Turn off the host device.
2. Plug the male 10-pin RJ45 end of the
USB cable into the 10-pin socket on
the MS1690. There will be an audible
click
when the connector lock engages.
3. Plug the USB type A end of the USB
cable into the host’s USB port.
4. Turn on the host device.
5. The MS1690 will start to initialize. All
LEDs (yellow, white, and blue) will light
for approximately 2 seconds then start
to alternately flash. When the scanner
has finished initializing the LEDs will
stop flashing and the unit will beep
3 times indicating that the scanner is
ready for use.
As a default, the MS1690-38 leaves the factory with USB Keyboard
Emulation Mode enabled.
For information on configuring the MS1690-38 for USB Serial Emulation
Mode, please refer to the USB section of the MetroSelect Single-Line
Configuration Guide (
MLPN
00-02544).
Plugging the scanner into a port on the host device does not guarantee
that scanned information will be communicated properly to the host
device. The scanner is shipped from the factory configured with default
settings. Please refer to the MetroSelect Single-Line Configuration
Guide (
MLPN
00-02544) or MetroSet
2
’s help files for instructions on
changing the scanner’s configuration. In addition, please check that the
scanner and host system are using the same communication protocol.
See power source caution statement located on page 6 of this manual.