Metrohm Easy PAT D2112 Скачать руководство пользователя страница 5

8.  LIMITED WARRANTY

Edgcumbe Instruments Limited warrant instruments and test equipment manufactured
by them to be free from defective material or factory workmanship and agree to repair
or replace such products which, under normal use and service, disclose the defect to be
the fault of our manufacturing, with no charge for parts and service.  If we are unable to
repair or replace the product, we will make a refund of the purchase price.  Consult the
Instruction Manual for instructions regarding the proper use and servicing of instruments
and test equipment. Our obligation under this warranty is limited to repairing, replacing
or making refund of any instrument or test equipment which proves to be defective
within twelve months from the date of original purchase.

This warranty does not apply to any of our products which have been repaired or altered
by unauthorised persons in any way  so as, in our sole judgement, to injure their stability
or reliability, or which have been subject to misuse, abuse , altered defaced or removed.
Accessories, not of our manufacture used with this product are not covered by this
warranty.

To register a claim under the provisions of this warrant, return the instrument or test
equipment to Edgcumbe Instruments Limited, Main Street, Bothwell, Glasgow, G71
8EZ. Upon our receipt and inspection of the product we will advise you as to the
disposition of your claim.

ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD
OF TWELVE MONTHS, AND THE PROVISIONS OF THE WARRANTY ARE
EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR
IMPLIED.

The purchaser agrees to assume all liability for any damages and bodily injury which
may result from the use or misuse of the product by the purchaser, his employees, or
others, and the remedies provided for in this warranty are expressly in lieu of any other
liability Edgcumbe Instruments Limited may have including incidental or consequential
damages.

Edgcumbe Instruments Limited reserve the right to discontinue models at any time, or
change specification, price or design, without notice and without incurring any obligation.

Fig. 1

2.

GENERAL DESCRIPTION

The Metrohm EasyPAT is an LCD indicating portable appliance tester, which is housed in a
rugged injection moulded case with a removable lid. The base of the case contains the complete
power and electronic circuitry. 

B

asic safety instructions are presented on the inside of the lid,

and a pannier bag, which provides storage  for the flash gun, supply adapters and comprehensive
instruction manual, clips onto the top of the lid.

Operation of the Metrohm EasyPAT is straightforward. The five tests, continuity, insulation,
run current, run  leakage and flash, provided by this instrument are selected by depressing one
of five push-button switches on the front panel. A three position rocker  switch  selects a test
current of 100m A d.c., 8A a.c. or 25A a.c. for  the continuity test. While the key is depressed
the relevant measurement is displayed on the large, custom LCD Display.

The Metrohm EasyPat allows fast, simple testing on all tools, appliances and I.T equipment in
accordance with the recommendations of the Electricity At Work Act, the Health And Safety
Executives and the Electronic And Business Equipment Association. It should be noted that

-2-

-13-

Содержание Easy PAT D2112

Страница 1: ...Main Street Bothwell Glasgow G71 8EZ U K Tel 44 0 1698 852574 Fax 44 0 1698 854442 E mail support metrohm demon co uk CMR0090 Issue 1 2 98 EasyPAT LCD INDICATING PAT MODEL D2112 INSTRUCTION MANUAL Ed...

Страница 2: ......

Страница 3: ...ENTS i 1 SAFETY RULES 1 2 GENERAL DESCRIPTION 2 5 3 OPERATING INSTRUCTIONS 5 9 4 SPECIFICATIONS 9 4 1 ELECTRICAL 9 11 4 2 MECHANICAL 11 4 3 ENVIRONMENTAL 11 5 CLEANING 12 6 SPARES AND ACCESSORIES 12 7...

Страница 4: ...structions before attempting to use this tester Do not exceed the limits of this tester SAFETY CHECK Double check the lead connections before making a test Are you following all the instructions When...

Страница 5: ...Y OTHER WARRANTIES EXPRESSED OR IMPLIED The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser his emplo...

Страница 6: ...a limiting resistor selected by the three position rocker switch The high current applied in this test verifies that the protective earth path will carry the fault current in the event of an insulatio...

Страница 7: ...at the current flow in the earth lead is monitored to check that no potentially hazardous voltage induced earth leakage paths are created when the appliance is operating 6 FLASH This is an optional te...

Страница 8: ...Switch Carefully fit the wander earth lead to any exposed earthed metal on the appliance then press and hold the CONT key The display will show the measured continuity value for the appliance for as l...

Страница 9: ...ing by 0 1 and multiply by length for 0 1 e g Maximum cable length for 0 5mm2 on 0 1 setting 2 metres Maximum cable length for 0 5mm2 on 0 2 setting 0 2 0 1 x2 4 metres NOTE During this test high curr...

Страница 10: ...lash probe for damage before use Flash voltage is applied i Along the mains lead phase neutral and the earth for a Class I instrument test voltage 1 5kV ii Along the mains lead phase neutral and the f...