metrofires ECO Insert Скачать руководство пользователя страница 1

• ECO Trend Insert

ECO Insert Models

Wood Fire 

Installation & Owner’s Operation Manual

M1006 01/13

PO Box 11, Inglewood 4347, New Zealand
Ph (06) 756 6520 •  Fax (06) 756 6540
[email protected] • www.metrofires.co.nz

Installation Important information ................... 2
Assembling your Metro ...............................2-3
Floor protector requirements ......................... 4
Installing your Metro ...................................... 4
Operation Important information .................... 5
Where to install a Metro in your home ............ 6

Getting to know your Metro ........................... 6
Operating your Metro .................................... 6
Cleaning and maintenance  ........................7-8
Troubleshooting ............................................. 9
Metro warranty ............................................ 10
Pioneer wood fire accessories ..................... 11

Содержание ECO Insert

Страница 1: ...fires co nz www metrofires co nz Installation Important information 2 Assembling your Metro 2 3 Floor protector requirements 4 Installing your Metro 4 Operation Important information 5 Where to instal...

Страница 2: ...Zealand the Metro must be bolted through the floor protector into the floor to comply with the seismic restraint provisions of AS NZS 2918 2001 The Metro fascia is coated in vitreous enamel or high t...

Страница 3: ...to retain the side bricks in position refer Diagram 2 this page Remove the cabinet top which is packed inverted on top of the firebox and fit it into position over the cabinet sides as detailed in Dia...

Страница 4: ...baffle from inside the fireplace insert and the removable cabinet top Check that the flue stub of the fireplace insert is in line by looking down the chimney if not a stainless steel offset or flexi f...

Страница 5: ...ritical that the fire not be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s this will cause air to leak into the fire causing the...

Страница 6: ...Metro wood fire METRO INSERT AIR CONTROL Operating your Metro wood fire If your Metro has only been installed within the past few days the fire cement seal at the base of the flue will not be fully cu...

Страница 7: ...m which will usually be sufficient Retighten then repeat by loosening the lower hinge nut this time applying a slight downwards pressure onto the door to move the lower hinge assembly back a similar d...

Страница 8: ...lt in more creosote build up in the flue pipe Pioneer produce a telescopic fluebrush system which is available from your Metro retailer To clean the flue pipe of your Metro proceed as follows Open the...

Страница 9: ...ues but if you have an ECO Cowl fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Cowl is shorter in length Directional Cowl designed for high wind areas A...

Страница 10: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 11: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...