INSTALLATION & SET-UP

  9

3 . 1. 8 MAC FCS

On older units, bit-switch 7 enabled the transmission of the MAC FCS. This feature has now 
been removed and the WC3445 always strips the MAC FCS from the ethernet packet. .

3 . 1. 9  E3 Line port

No configuration of the E3 Line port is required. Operation is unframed. The Line Coding 
setting is built into the unit (no bit-switch) and cannot be altered. It is HDB3 (High-Density 
Binary 3). The maximum line rate is 34.368 Mbps. The maximum corresponding packet rate 
is 64120 packets per second.

3 . 1. 10 DS3 Line port

No configuration of the DS3 Line port is required. Operation is unframed. The Line Coding 
setting is built into the unit (no bit-switch) and cannot be altered. It is B3ZS (Binary 3 zero 
suppression). The maximum line rate is 44.736 Mbps. The maximum corresponding packet 
rate is 82236 packets per second.

3. 2 Connecting up
Safety Notice: 

Ports that are identified as SELV in this manual should only be connected to 

SELV ports on other equipment in accordance with EN 60950 clause 2.3.

Step 1: Mounting

.

The WC3445 is housed in a convenient 1U table top enclosure. 19 inch rack-mount options 
are also available, as well as rack nests for two or 18 units.

Step 2: Set up bit-switches 

These switches are located on the base of the unit and are used to configure the unit.
 

Step 2: LAN ports

Connect the WC3445 to the LAN ports using the four labelled RJ45 ports on the rear panel.

Step 3: E3/DS3 Line (WAN)

Connect the WAN by means of  the two BNC bayonet connectors labelled  LINE Rx and 
LINE Tx. Remember to set the 

PORT

 

SELECT

 bip-switch to the correct interface type before 

connecting.

Step 4: Power Supply

Finally, connect the mains power  and re-check all connections for security. Then turn on the 
power supply. Check the rear panel status LED to ensure that it is continuously lit (green).

Warning: 

Do not connect the WC3445 to excessive voltage. Read the safety information 

before continuing.

Содержание WAN-in-a-CAN WC3445

Страница 1: ...y Way Egham Surrey TW20 8RY United Kingdom tel 44 0 1784 744700 fax 44 0 1784 744730 email support metrodata co uk Part No 76 02 054E website www metrodata co uk support Metrodata WAN in a CAN WC3445...

Страница 2: ...end upon the user s network design and workload characteristics The WC3445 Ethernet Switch can switch between local LANs connected to its four ports and the unit may thus reduce the need for local LAN...

Страница 3: ...terminated to the screened connector shell and not connected to any pins of the connector Failure to use the correct connector may compromise EMC compliance 1 5 EN55022 Declaration The WC3445 is a Cl...

Страница 4: ...igure 2 2 Rear panel status LED 2 3 Status display LAN ports Each LAN port RJ45 connector on the rear panel has two miniature LEDs mounted on it The left hand green LED shows link activity and the rig...

Страница 5: ...200 100mA A Buccaneer type socket is fitted to the rear panel and a plug is provided with the unit for the customer s own wiring The connections are labelled on the rear panel of the WC3445 On some u...

Страница 6: ...gure 2 5 Cable lengths Note The total maximum attenuation of each of the cables attached to the network port must not exceed 6dB when measured at 17 184 MHz E3 or 22 368 MHz DS3 The frequency attenuat...

Страница 7: ...plex mode There is a miniature LED on the lower right corner of each RJ45 socket on the rear panel which is illuminated yellow when operation is at 100 Mbps The miniature LED on the lower left corner...

Страница 8: ...PRBS test Normal Enabled 7 LAN Mode 100M FD Auto negotiate 8 Auto MDI MDI X Disabled Enabled WC3445 LAN TO E3 DS3 CONVERTER AC Metrodata Ltd TW20 8RY UK Tel 44 0 1784 744700 Fax 44 0 1784 744730 Part...

Страница 9: ...ribed in the next section The switch is set to ON for normal operation NONE of the unit without any loopbacks With the switch set to OFF Loopback is applied so that Transmitted data Received data on t...

Страница 10: ...Safety Notice Ports that are identified as SELV in this manual should only be connected to SELV ports on other equipment in accordance with EN 60950 clause 2 3 Step 1 Mounting The WC3445 is housed in...

Страница 11: ...n the two WC3445 units to the rackmount adaptor plate using the screws that you have removed as shown in the illustrations below Then secure the rack mounting plate complete with the two WC3445 units...

Страница 12: ...plan elevation Recessed space to accommodate fibre bends WC3445 WC3445 Part No 80 05 256 SUBSCRIBER PORT 10 100 BASE T Green Link Act Yellow Speed Tx Rx Line Activity 1 2 3 4 SUBSCRIBER PORT 10 100 BA...

Страница 13: ...nvestigatory action should be taken on the LAN and or its cables Step 3 Establish and verify the WAN links If there is LAN activity then check for WAN activity by observing the green Tx and Rx LED s o...

Страница 14: ...esents a fixed MDI X interface to the LAN Note that for 100M full duplex operation between the WC3445 and a fixed i e non negotiating LAN port bit switch 7 must be set to 100M FD If this is not done t...

Страница 15: ...lerance Per G 823 Barrier EN 41003 compliant barrier provided on the E3 DS3 interfaces Framing Unframed Encapsulation HDLC Clocking options E3 DS3 LINE port Internal or Loop Line Rate E3 34 368 Mbps D...

Отзывы: