13
Installation Guide
Chapter 2: Installation Guide
Safety Warning
Electrostatic Discharge Warning
Electrostatic discharge precautions should be taken when handling any
line card. Proper grounding is recommended (i.e., wear a wrist strap).
1. Unpack the Line Card
Your order has been provided with the safest possible packaging, but
shipping damage does occasionally occur. Inspect your line card
carefully. If you discover any shipping damage, notify your carrier and
follow their instructions for damage and claims. Save the original
shipping carton if return or storage of the card is necessary.
2. Set the Switches
A bank of six DIP switches is located on the back of the card. These
switches allow you to select from several modes of operation that only
affect the access port (Port 1). Functional switches are clearly marked on
the card’s circuit board. Refer to the following table for the proper setting
of the DIP switches.
When setting DIP switches, the UP position is when the lever of the DIP
switch is pushed away from the circuit board. The DOWN position is
when the lever is pushed toward the board.
!
Default Switch Settings
DOWN
UP
1 2 3 4 5
DUP1
AN1
6
SPD1