Connect to the Network
A total of three connections must be made on the front panel when
connecting the line card to the network. Make sure that all cards are
firmly secured to the chassis before making network connections.
•
Connect to the MAIN port.
The Radiance redundant interface line card provides one
shielded RJ-45 jack for 10BASE-T connections and supports a
maximum segment length of 100 meters over Category 3, 4 or
5 twisted-pair cable.
Refer to STEP 3 for MDI-
II
to MDI-X switch functionality.
Before making the proper twisted-pair connection, verify the
port configuration of the connected device.
If you do not know the internal wiring configuration of the
other device’s RJ-45 port, consult the product documentation.
5
•
Connect to the PRIMARY port.
•
Connect to the SECONDARY port.
The R711-11 and R712-11 provide two additional RJ-45 jacks
for 10BASE-T connections and support a maximum segment
length of 100 meters over Category 3, 4 or 5 twisted-pair cable.
Embedded Parallel Function
A device that is wired straight through, needs one crossover connection:
If the cable is…
straight through
crossover
… the MDI-II to MDI-X Switch Setting should be
X
II
TD+
TD-
RD+
RD-
“redundant twister”
TP Port Configuration
Device with Straight Through
TP Port Configuration
“redundant twister”
TP Port Configuration
Typical Hub
TP Port Configuration
TD+
TD-
RD+
RD-
Embedded Crossover Function
MDI–X
MDI
TD+
TD-
RD+
RD-
1
2
3
6
1
2
3
6
1
2
3
6
1
2
3
6
TD+
TD-
RD+
RD-
A device that is wired crossover, needs a parallel connection:
If the cable is…
straight through
crossover
… the MDI-II to MDI-X Switch Setting should be
II
X