8201-001, Conduit Union

Fits between transmitter and 8200-001 conduit elbow to facilitate installation and 

wiring where there is not enough room to rotate the elbow.  Suitable for Class I, Div. 

1 (Grps A, B, C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. Material: zinc 

plated steel.

7084-001, Stainless Steel Flange Mount Adaptor

Provides a means to surface mount transmitters rather than NPT stud (½”: NPT center 

hole).  Three equally spaced 6.6 mm (0.26’) diameter mounting holes on 38 mm  

(1.50”) diameter circle.

7084-002, Flange Mount Adaptor

Same as 7084-001, except center hole is ¼” NPT.  Material: stainless steel

8253-002, Bushing

Bushing for ½” NPT mount when screwed onto standard ¼” NPT base. Material: stain

-

less steel.

8169-75-002-XXX, Two-wire, Cable Assembly

2 conductor (20 AWG) twisted, shielded PVC jacketed cable, with plated steel grip for 

cable strain relief, male ¾” NPT end.  Specify -XXX for length in feet.  Example:  8169-

75-002-010 =10 ft (3.1M). Material: zinc plated steel.

93818-004, Cable Grip Strain Relief Fitting

3/4” NPT male thread to cable grip. Diameter range: .156” to .25”. Complete with 

sealing ring, locknut and hot dip / mechanically galvanized finish. Suitable for NEMA 4 

enclosures.

93818-018, Armored Cable Grip Strain Relief Fitting

3/4” NPT male thread to cable grip. Armor diameter range: .40” to .50”. Complete 

with sealing ring, locknut and a hot dip / mechanically galvanized finish. Suitable for 

NEMA 4 enclosures.

CONNECTION

OPTIONAL ACCESSORIES

The ST5491E is available with different mounting options. The performance of the transmit

-

ter does not change (except for the dynamic output option, discussed). 

MOUNTING

Содержание ST5491E

Страница 1: ...nal conditioner in a single package They provide the ideal solution for sensing machinery vibration level and transmitting a proportional 4 20 mA signal directly to a PLC DCS monitor or computer Typic...

Страница 2: ...wrench A pipe wrench can apply extreme forces to the body and potentially damage electronic components A minimum of five threads of engagement should be made A 1 4 inch to 1 2 inch NPT bushing is avai...

Страница 3: ...rocedures 3 ELECTROMAGNETIC COMPATIBILITY To meet the requirements of electromagnetic compatibility in areas of high electromagnetic interference the field wiring must be 1 Shielded twisted pair cable...

Страница 4: ...will not measure side to side motion It measures velocity vibration in ips inches per second Velocity vibration is a common mea surement for a large variety of machinery Figure 1 shows a typical tran...

Страница 5: ...MITTER MODEL 8170 XXX MODEL 7084 XXX FLANGE MOUNTING ADAPTER OPTIONAL i I 1 i AXIAL VIEW FLEXIBLE WEATHER TIGHT CONDUIT OPTIONAL 2 OF FLEX MAX SHAFT ORIENT STUD DIRECTLY TOWARD SHAFT CENTERLINE BEARIN...

Страница 6: ...ibration free surface for this measurement Often a piece of foam can be used to isolate the transmitter from external motion 2 Span Verification Subject the transmitter to a known vibration within the...

Страница 7: ...aterial stain less steel 8169 75 002 XXX Two wire Cable Assembly 2 conductor 20 AWG twisted shielded PVC jacketed cable with plated steel grip for cable strain relief male NPT end Specify XXX for leng...

Страница 8: ...ectronic equipment was manufactured according to high quality standards to ensure safe and reliable operation when used as intended Due to its nature this equipment may contain small quantities of sub...

Отзывы: