Temperature: °C, °F, K in TK/TJ or Pt100/Pt1000
Display in
REL
mode
:
°C
by Pt1000
g
raphic display
:
Direct measurement of current:
Current with clamp:
Secondary modes accessible via MEAS…:
y
TREND
: graphic display
y
REL
:
relative mode (REF,
Δ
,
Δ
%)
y
SURV
:
surveillance mode (MIN, MAX, AVG)
y
SPEC
:
specifications (SMIN, SMAX, %, digits)
y
MEAS+
: to access the secondary functions
SETUP Menu:
This
SETUP
menu sets the parameters through main adjustments
and 3 levels:
1. General Setup
y
Util
:
lighting, standby, beep, language, clock
y
Comm:
IR or BT type, baud IR, protocol: SCPI or MODBUS
y
Power supply
: battery or rechargeable battery, capacity
2. Measurement config
y
Measure:
filter on or off, impedance, reference, dBm and W
y
Clamp:
V or A measurement, ratio, unit
y
Math:
measurement, coefficient A and B, unit
3. Configuration and MTX identification
y
Memory
: files, numbers of recordings, frequency
y
Config
:
factory configuration, USER or BASIC start
y
About
:
model, serial number, software version
SURVEILLANCE mode: MEAS/SURV
MATH function:
Function Ax + b configurable to obtain a direct reading of
the original quantity.
Parameters to be adjusted:
MATH function, recall in the secondary function:
V Meas…/ MEAS+:
Memory mode: Mem…
COM
input
V
input
Activate
T°.
y
1
st
press on F1 / F2 / F3
Æ
°C
,
°F
,
K
y
2
nd
press
Æ
Pt100
,
Pt1000
y
3
rd
press
Æ
TC J
or
TC K.
A
input
COM
input
Activate or deactivate the selected
mode by pressing the
MEAS…
key
then F1 / F2 / F3 / F4.
1. Activate the
"
clamp
" function.
2. Select the coupling,
then
2
nd
press on
SETUP
menu:
MEASURE or input
V or A.
3. Enter the
ratio
of the clamp:
0001.0A / 0001.0V
(default)
by
pressing .
4. Select the unit,
A
(default).
SETUP
menu
Activate or start,
deactivate or stop
the
SURV
mode
by pressing on
F1/F2
.
1. Open "Menu" using the
SETUP
key, then
MATH
.
2. Select the
V, A,
Ω
or Hz
function by the keys:
F1, F2, F3, F4.
3. Select and enter the
A
or
B
coefficients.
4. Select the unit.
1. Activation by the
SETUP
menu or long press on
Mem:
2. Select and modify the parameters:
y
Files:
list of the stored files, by date and time
y
Nb. rec.
: number of recordings
Æ
max. 6500
y
Freq
: recording frequency in h, min, s
Activate / deactivate the
MEM
auto recording
mode by a short press:
max.10 sequences
Pressing F3 in SURV opens a consultation
window of CONSULT records:
A long press on
Mem…
opens the record consultation
menu: File
Æ
F1:
1. Display or open the list by F1.
2. Select a file with the keys
.
3. Validate it to display by the F1 key
,
then
Open.
4.
Erase
a sequence or
Erase all
memory sequences.
Pt100
Pt1000
TC J
TC K
°C
°F
K
REL
Reference
Δ
difference
Δ
% difference in %
1. Activate
A,
then
activate the AC or
DC or AC+DC
coupling by
pressing F1 / F2 /
F3,
2. Select
SETUP/MEASURE
to adjust the
parameters: filters,
impedance,
reference, etc.
MATH function result
in
secondary
function
and displayed main
quantity
Incrementing
the number of
steps since
startup