4  Button function: 

Push 

IN-OUT

 button to select to show INSIDE or OUTSIDE temperature 

  (IN or OUT will be indicated on LCD screen) 

Push 

MAX-MIN

 button to show recorded MAXIMUM or MINIMUM temperature 

and humidity value (MAX or MIN will be indicated on LCD screen) 

*  Push 

/

 button to change temperature display unit 

*  Push 

RESET

 button to make all set and recorded values to the original ones 

   

5  Operation: 

5-1  Install battery and start the meter 

  [a] take off the battery cover according to the arrow indicated on it 

 

[b] install 2 x 1.5 VV (AAA size) battery strictly according to the NEGATIVE and 
POSITIVE symbol indicated inside the battery compartment 

  [c] push on the battery cover, the meter then starts to work 

5-2  INSIDE and OUTSIDE house temperature measuring 

 

[a] Push the sensor wire plug into the socket under battery cover and place the 
sensor out of the house 

 

[b] push 

IN-OUT

 button to select to show INSIDE or OUTSIDE temperature 

      (IN or OUT will be indicated on the left side of TEMP. value) 

 

Note:   
[a]    This meter can only measure INSIDE house humidity ( IN is always shows   

above the humidity unit symbol % ) 

[b]    If the sensor wire for OUTSIDE temperature is not installed to this meter, the   

meter can only show INSIDE temperature 

5-3  Environmental Comfort Status Indicating   

 

The meter can automatically indicating Environmental Comfort Status basing 
on the humidity and temperature value it measures, it will indicates 3 kinds 
status according to the below chart: 

 
 

 

Symbol Indicated 

for Comfort Status   

temperature 

humidity 

meaning 

COM 

20~25

 

(68~77%

40%~70% RH 

comfortable 

WET 

 

>70% RH 

wet 

DRY 

 

<40% RH 

dry 

No Symbol 

>25

(77

<20

(68

 

40%~70%RH 

Not comfortable 

scope 

(Humidity 40~70%) 

 

 
 
 
 
 
 
 