MI 3099  

 

Demonstration board 

 

1.3  Meaning of front panel warnings 

 

 

Take care. Demonstration board operates only at 
declared mains voltages (according to the description 
under the mains socket) and right connected mains 
terminals! 
 
Use only outlets with grounded protection terminal! 
 
There is a protection circuit inside the board. The 
board will not turn on: 

− 

if PE terminal is not grounded 

 

− 

if N terminal is not connected 

 

− 

if phase voltage is not applied to the boards L 
terminal. Swap the mains plug in this case.

 

 

− 

if there is a voltage difference higher than 30V 
between N and PE terminals. 

 
1-phase connection: The board will turn on if mains 
plug is inserted correctly. Otherwise swap L and N 
terminals!

 
 
 
 

 

Use the test outlets on front panel only for 
demonstration purposes! 
 
Do not connect any other equipment/loads, otherwise 
the board may be damaged and the operator exposed 
to hazardous voltage! 
 
Do not connect any external voltage except voltages 
generated by measuring instruments – possible 
hazardous voltage on accessible parts of board. 
 

 
 
 

 

PE terminals collectors and N terminals collectors are 
NOT connected to mains PE terminal but to neutral 
line. 

 

Содержание MI 3099

Страница 1: ...n board MI 3099 Instruction manual Version 1 0 Code No 20 750 997 KOMETEC Karl Oelkers e K Mess und Pr fger te Shop Mozartstr 10 D 88097 Eriskirch T 07541 955 1313 F 07541 955 1131 info kometec de www...

Страница 2: ...etrel si 2004 2006 METREL Mark on your equipment certifies that this equipment meets the requirements of the EU European Union concerning safety and interference causing equipment regulations No part...

Страница 3: ...eral Description 4 1 2 General warnings 4 1 3 Meaning of front panel warnings 5 2 Front panel and mains cable description 6 2 1 Front panel 6 2 2 Mains cable 3 phase 7 3 Technical data 7 4 Maintenance...

Страница 4: ...l warnings Connect Demonstration board to outlets with well grounded protection terminal only Line impedance ZLN of outlet must be less than 1 If Demonstration board is not used in a manner specified...

Страница 5: ...Swap the mains plug in this case if there is a voltage difference higher than 30V between N and PE terminals 1 phase connection The board will turn on if mains plug is inserted correctly Otherwise sw...

Страница 6: ...connection to 1 phase system use the 1 phase to 3 phase adapter 2 Main switch 3 RCD protection device It can be by passed with rotary switch position 6 4 N collector 5 PE collector 6 Rotary switch for...

Страница 7: ...ry CAT II 300 V Pollution degree 2 Reference conditions Reference temperature range 10 C 30 C Reference humidity range 40 RH 70 RH Operation conditions Working temperature range 5 C 40 C Maximum relat...

Страница 8: ...e Consult the producer or your dealer for further information The product has no internal user serviceable parts fuses etc 5 Standard set Upon receipt of Demonstration board it is advisable to check t...

Отзывы: