MI 2893 / MI 2892 / MI 2885
Technical specifications
214
6
Technical specifications
6.1
General specifications
Working temperature range:
-20
C ÷ +55
C
Storage temperature range:
-40
C ÷ +70
C
Max. humidity:
5 ÷ 98 % RH (0
C ÷ 40
C), non-condensing
Pollution degree:
2
Protection classification:
Reinforced insulation
Measuring category - MI 2893
CAT IV / 600 V;
For three phase connection CAT III / 1000 V;
Measuring category - MI 2892/MI 2885
CAT IV / 600 V; CAT III / 1000 V;
Altitude
up to 3000 meters above sea level
Protection degree:
IP 40
Indoor use
IP 65 with A 1565 waterproof mounting case
Outdoor use
Dimensions:
23 cm x 14cm x 8 cm
Weight (with batteries): MI 2893
1.1 kg
Weight (with batteries): MI 2892/MI
2885
0.96 kg
Display:
Colour 4.3 TFT liquid crystal display (LCD) with backlight, 480
x 272 dots.
Memory:
8 GB microSD card provided; max. 32 GB supported
Batteries:
6 x 1.2 V NiMH rechargeable batteries
type HR 6 (AA)
External DC supply - charger:
100-240 V~, 50-60 Hz, 0.4 A~, CAT II 300 V
12 V DC, min 1.2 A
Maximum supply consumption:
MI 2893
12 V / 410 mA – without batteries
12 V / 1.2
A – while charging batteries
Maximum supply consumption:
MI 2892/MI 2885
12 V / 300 mA – without batteries
12 V / 1
A – while charging batteries
Battery charging time:
3 hours*
Communication:
USB 2.0
Standard USB Type B
Ethernet
10Mb
* The charging time and the operating hours are given for batteries with a nominal capacity of 2400 mAh without display illumination and
switching off the transient recorder during the powering via the batteries (valid for MI 2893).
6.2
Measurements
6.2.1
General description
Max. input voltage (Phase – Neutral): MI 2893
Three phase connection: 50 … 1000 V
RMS
Phase connection: 50 … 500 V
RMS
Max. input voltage (Phase – Neutral):
MI 2892/MI 2885
Three phase connection: 50 … 1000 V
RMS
Max. input voltage (Phase – Phase):
87 … 1730 V
RMS
Max. transient peak voltage